background image

Rx450AC Rx550DC MK3 Installation Manual - V19 30Sep05.doc

Page 28/28

Other BBV products. 

 

Product Description 

TX300 

Single camera desktop telemetry transmitter with coax & 20mA 
telemetry, Pan/Tilt/Lens & Lights 

TX400 

As TX300 inc Wash, Wipe, Autopan, 8 presets, preset patrol. 

TX400DC 

As TX400 including joystick for proportional Pan/Tilt control. 

TX1000 

8 or 16 camera, 2 monitor telemetry transmitter. Up to 2 
keyboards and options for alarm inputs and 20mA telemetry. 

TX1500 

Mid size matrix 16 – 96 camera, 8 monitor. Up to 4 control 
positions (keyboard & remote control) options for alarms, remote 
control, coax and RS485 telemetry. 

FBM range 

Large size matrix. Configurable up to 1024 cameras and 64 
monitor outputs. Up to 8 control positions (keyboard & remote 
control) options for alarms, remote control RS485 telemetry with 
various options. 

 

 

RX100 

Dome Interface with options to drive a large library of dome 
cameras. Coaxial and 20mA telemetry. 

RX200 

AC receiver for Pan only heads or static cameras, 
Wash/Wipe/Lights. Coaxial and 20mA telemetry. 

RX300 

AC receiver for Pan/Tilt/Zoom/Focus/Iris Override and 1 
Auxiliary output. Coaxial and 20mA telemetry. 

RX400P 

AC full function receiver. PTZFI 4 Auxiliary outputs, 16 presets. 
Coaxial and 20mA telemetry. 

RX400DC 

24Vdc high/variable speed receiver. 16 presets, 8 local alarm 
inputs, 3 Auxiliary outputs, options to drive JVC TK-C1360 and 
Mitsi CCD400 cameras. Coaxial and 20mA telemetry. 

 

 

RX45X - RX55X 

Multi protocol RS485 

and BBV coax

 

RS485 and BBV coa  controllable AC and DC receivers. These 
receivers are controlled from an expanding choice of RS485 
protocols as listed below. 110/230Vac supply. PTZFI, 32 
presets, preset patrol, 8 local alarm inputs, 12V 500mA supply 
output. OSD for remote diagnostics. 3 Auxiliary outputs. 
Optional Privacy board. 
BBV RS485 and COAX, 
PELCO P/D RS485, 
VCL RS485, 
PHILIPS RS485 (OPTIONAL BI-PHASE INPUT), 
DENNARD RS485 

RX450/550 

PANASONIC RS485 Protocol only version of RX45X/55X. 

 

 

STARCARD 

8 * RS485 output with option of protocol conversion. 
STARCARD/CONVERTER 

 

 

ACCESSORIES 

TxLD   (bidirectional RS422-RS232 converter) 
98005 (bidirectional 20mA-RS232 converter) 

 

Содержание RX550

Страница 1: ...ex Park Diplocks Industrial Estate Hailsham East Sussex BN27 3JU UK Tel 44 0 1323 842727 Fax 44 0 1323 842728 Support 44 0 1323 444600 www bbvcctv com Model Shown RX550 RX550 and RX450 Panasonic RS485...

Страница 2: ...e internal electronics of this unit to water or dampness for example in an unprotected outdoor installation or in any area classified as a wet location The unit as supplied conforms to ingress protect...

Страница 3: ...alified technician to restore the unit to normal operation e If the unit has been dropped or the enclosure is damaged f If the unit exhibits a distinct change in performance This indicates a need for...

Страница 4: ...single telemetry output a BBV STARCARD CONVERTER can be used to allow star wiring of the site The receiver is supplied in an IP67 rated enclosure It will be necessary to make suitable holes in the en...

Страница 5: ...ed selectable via menu between 0 12Vdc 1 second inching built in Provides drive for Zoom Focus Each lens drive carries red and green LEDs to indicate direction and drive voltage Presets Inputs are pro...

Страница 6: ...Y ADJUSTABLE Adjustable via menu between 6 12Vdc Inching speed selectable via menu between 0 12Vdc 1 second inching built in Provides drive for Zoom Focus Each lens drive carries red and green LEDs to...

Страница 7: ...ily Prepare cables as follows 1 Use only cable between 0 08 and 2 5 mm 2 Strip the cable to a length of 5 to 6 mm 0 23 in The correct method of attachment is as follows 1 Press down the relevant termi...

Страница 8: ...d option Supply IN J3 aux link RED RED 110Vac IN 110Vac OUT Factory fitted option Supply IN BLUE BROWN J3 aux link 24Vac IN 24Vac OUT RX450 Mk 2 SERIES Factory fitted option J2 Supply IN 24Vac 24Vac G...

Страница 9: ...minated End Of Line Un Terminated Daisy Chained IRIS The IRIS output can be configured as motor drive or AutoIris Override voltage 8 7 6 5 4 3 2 1 1 T R A 2 T R B 3 G N D 4 R A 5 R B J4 RS485 Telemetr...

Страница 10: ...3 2 1 1 T R A 2 T R B 3 G N D 4 R A 5 R B J4 RS485 Telemetry Expanded View F2 PSU FUSE 3 15A Aux connectors Colour Coding BLUE NEUTRAL ORANGE LIVE GREEN EARTH 24Vac Mains RED RED BLUE BROWN Camera Rx...

Страница 11: ...correct and NOT crossed before powering up the receiver as damage could be caused Note that the lens outputs can be reversed from within the OPTIONS menu of the receiver menu Pin J5 Pan LEFT RED Pan R...

Страница 12: ...ore Lens drive preset inputs Termination fitted Address 01 WJ FS616 Multiplexer 230Vac Supply Spur to provide isolation Coax To WJ FS616 RS485 telemetry cable Pan Tilt Mechanism Housing Camera Multico...

Страница 13: ...e Keep stub length as short as possible Keep stub length as short as possible WJ FS616 Multiplexer Multiple Rx550 and RS485 controlled domes with WJ FS616 WJ FS616 Multiplexer Camera 1 Camera 2 Camera...

Страница 14: ...s dome Keep stub length as short as possible Keep stub length as short as possible RS485 Telemetry Connection details T B Rx550 Rx550 T A R B R A Rx550 Rx550 T B T A R B R A 4 WIRE 2 WIRE FS616 T R A...

Страница 15: ...ork must have a unique address The RS485 telemetry data can operate over either 2 or 4 wire cable The following diagram shows cable connections for 4 wire mode Ensure that the receiver is set to the s...

Страница 16: ...OWN to highlight RETURN and press SW2 MENU SET to return to previous menu i Use SW1 UP or SW3 DOWN to highlight RETURN and press SW2 MENU SET to exit from the menu The receiver will restart and you ca...

Страница 17: ...and alone receiver Please refer to earlier diagram for button positions The receiver OSD displays the self test progress with two status lines as shown below FUNCTION this line will show the current f...

Страница 18: ...EXIT from the MAIN MENU The receiver will now reset and resume normal operation The receiver menu can also be accessed remotely using the Panasonic controller by using the procedure used to access a...

Страница 19: ...otes Navigation UP and DOWN to move selected line LEFT or RIGHT is used to either select the submenu or cycle options NEXT will display the next screen of multi screen menus and BACK will display the...

Страница 20: ...llow setting of above RETURN Return to RECEIVER menu COMMUNICATIONS RX550DC PRESET MENU PATROL DWELL OM 5 Dwell in minutes seconds during preset patrol DISPLAY PAT YES Display preset number during pat...

Страница 21: ...be reversed DATUM DELAY OM 0 Time in minutes seconds to return to preset 1 0 never WASH DELAY SECS 5 Seconds that WASH output is active following WIPE NEXT Display the OPTIONS MENU 2 OPTIONS RX550 DC...

Страница 22: ...to factory defaults All preset patrol settings etc will be cleared CLEAR ALL PRESETS Erase ALL preset positions only A second menu will be displayed to display an ARE YOU SURE message RETURN RETURN t...

Страница 23: ...set the minimum and maximum speeds during manual control MIN PAN 15 255 is maximum speed and 0 is minimum MAX TILT 255 If the minimum is too low the head may stall at low MIN TILT 50 speeds To increas...

Страница 24: ...accessed using the AUTOPAN menu This is displayed when the AUTO key is pressed and appears as follows Pressing the AUTOPAN key displays this menu Use the UP DOWN keys to choose a line and LEFT or RIG...

Страница 25: ...M 6 ON ALARM 7 ON ALARM 8 ON NEXT Return to the AUTOPAN MENU ALARMS Use the UP and DOWN keys to select an alarm input The Left or Right key will toggle the state from ON OFF When the alarms have are c...

Страница 26: ...Rx450AC Rx550DC MK3 Installation Manual V19 30Sep05 doc Page 26 28 Blank for your notes...

Страница 27: ...Rx450AC Rx550DC MK3 Installation Manual V19 30Sep05 doc Page 27 28 Blank for your notes...

Страница 28: ...an only heads or static cameras Wash Wipe Lights Coaxial and 20mA telemetry RX300 AC receiver for Pan Tilt Zoom Focus Iris Override and 1 Auxiliary output Coaxial and 20mA telemetry RX400P AC full fun...

Отзывы: