Rx450AC Rx550DC MK3 Installation Manual - V19 30Sep05.doc
Page 20/28
THE RECEIVER MENU SYSTEM IN DETAIL
Please refer to the menu structure on the previous page to help navigation through the
menu structure.
RX550 DC COMMS MENU
UNIT TYPE PANASONIC
UNIT ADDRESS 1
This is the address between 1 and 255 and must be unique
BAUD RATE 9600
RS485 baud rate 1200/2400/4800/
9600
/19200
TELEM DATA 4 WIRE
2 WIRE/
4 WIRE
RS485 network from Panasonic controller
DELAY TIME OFF
TX/RX delay 10/20/40/100mS/
OFF
for use with RF links etc
MENU UNLOCK LOCKED
Must be set to UNLOCKED to allow setting of above
RETURN
Return to RECEIVER menu
COMMUNICATIONS
RX550DC PRESET MENU
PATROL DWELL OM 5
Dwell in minutes & seconds during preset patrol
DISPLAY PAT YES
Display preset number during patrol (
YES
/NO)
PRESET NUMBER 1
Toggle current preset (1 - 32)
DELETE ? ACTIVE
Delete current preset, DEL if preset not present
PATROL A INC IN
Include preset in patrol (
IN
/OUT)
INDIVID DWELL NA
Override patrol dwell for this preset minutes & seconds
RETURN
Return to RECEIVER menu
PRESETS
RX550DC ALARM MENU 1
ALARM 1 ON
Each local alarm input can be disable or enabled
ALARM 2 ON
individually.
ALARM 3 ON
Setting to OFF disables the alarm input
ALARM 4 ON
and setting to ON enables the alarm input
ALARM 5 ON
ALARM 6 ON
ALARM 7 ON
ALARM 8 ON
NEXT
Display the ALARM MENU 2
ALARMS