
Error information page
When [Error (Detail)] or [Warning (Detail)] is displayed in the [SELF TEST] display field of the
[Projector status]
screen, click it to display the content of the error/warning.
f
The projector may go into the standby status to protect the projector depending on the contents of the error.
1
VX61
1 Self-diagnosis result display
Displays the item check results.
[OK]:
Indicates that operation is normal.
[FAILED]:
Indicates that there is a problem.
[WARNING]:
Indicates that there is a warning.
r
[FAILED] items displayed when a problem occurs
Parameter
Description
[FAN]
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
[FAN(INTAKE1)]
Trouble has occurred in the intake fan 1.
[FAN(INTAKE2)]
Trouble has occurred in the intake fan 2.
[FAN(INTAKE3)]
Trouble has occurred in the intake fan 3.
[FAN(LAMP)]
Trouble has occurred in the luminous lamp cooling fan.
[FAN(EXHAUST)]
Trouble has occurred in the exhaust fan.
[FAN(POWER)]
Trouble has occurred in the power fan.
[INTAKE AIR TEMPERATURE] The environment temperature is too high. Use under the proper operating environment temperature
*1
.
[EXHAUST AIR
TEMPERATURE]
The environment temperature is too high or the air exhaust port may be blocked. Use under the proper
operating environment temperature
*1
and check that the air exhaust port is not blocked.
[DC OUT]
The device which exceeds the rated power (DC 5 V, maximum 2 A) is connected to the projector. Remove
the device and then switch off and on the power of the projector.
[LAMP REMAIN TIME]
The luminous lamp runtime has exceeded the prescribed cumulative time, and it is now time to replace the
lamp unit.
[LAMP STATUS]
The luminous lamp has failed to light.
Wait a short while for the luminous lamp to cool off, and then turn on the power.
[APERTURE (CONTRAST-
SHUTTER)]
Trouble has occurred in the contrast shutter circuitry. Consult your dealer.
[AIR FILTER]
There is too much dust accumulated in the air filter unit. Turn off the projector and unplug the power plug
from the wall outlet, then maintain the air filter unit.
*1 For the operating environment temperature of the projector, refer to “Operating environment temperature” (
x
page 123).
92 -
ENGLISH
Chapter 5 Operation of Function - Web control function
Содержание PT-VX61K
Страница 32: ...Chapter 3 Basic Operations This chapter describes basic operations to start with 32 ENGLISH...
Страница 86: ...Chapter 5 Operation of Function This chapter describes the operation methods of some functions 86 ENGLISH...
Страница 113: ...Chapter 7 Appendix This chapter describes specifications for the projector ENGLISH 113...