background image

- 1 -

Safety Precautions 

  Be sure to thoroughly read the instruction manual before using the products. 
  Keep the instruction manual in a safe, convenient location for future reference. 
  All or part of the contents described in this manual may be changed without any notice. 
  Due to our constant striving for further improvement of products, parts or products that differ from those 

described in this manual may be substituted. 

          WARNING 

(Failure to observe this WARNING may cause a fatal or serious injury.) 

  Be sure to confirm that any peripheral equipment does not move before installation work. 

In addition, observe safety requirements for installation work where high-place work is expected. 

  Be sure to turn off the power source before wiring, mounting and transportation work.    (Failure to observe 

this WARNING may result in an electric shock/ injury or equipment damage due to short-circuit.) 

  Carry out wiring work correctly with reference to a proper drawing. 
  Never disassemble the equipment.    (Failure to observe this WARNING may result in an electric shock.) 
  Do not open the cover under an explosive environmental condition when power is entered.    (Failure to 

observe this WARNING may result in an injury or equipment damage.) 

  Do not place or store the equipment in any hostile environmental place where it will be subjected to direct 

sunlight, rain, water droplet, hazardous gas/water, etc.. 

          CAUTION 

(Failure to observe this CAUTION may cause a moderate injury or equipment damage.) 

  Do not use the equipment for any purpose other than the original purpose of use. 
  Be sure to confirm the specification of equipment and use the equipment within the range of specification. 

(Mounting conditions such as temperature, power source, frequency, etc.) 

  Make sure a correct wiring before applying power source. 
  Do not have a shock or strong impact to the equipment. 

(Failure to observe this CAUTION may result in equipment damage.) 

  Be sure to connect necessary terminals (grounding, etc.). 
  Remove all wiring to the equipment before doing electrical welding work near the equipment. 
  Do not forcedly bend or pull the lead wire also do not use unnecessarily long wire. 
  Tighten the cover, lead outlet, etc. properly so that dust, rainwater, etc. do not enter inside the equipment. 
  Do not use the equipment under a corrosive condition (NH

3

, SO

2

, CI

2

, etc.). 

  Be sure to tighten the cable grand so that outer air does not enter inside the equipment. 
  When applying piping connection such as conduit, etc. instead of cable grand, apply putty or equivalents 

on the cable entry so that outer air does not enter inside the equipment. 

Do not directly touch the probe with hands regardless of power ON or OFF. 
If you unavoidably have to touch the probe with hands when installation or maintenance process, be sure 
to turn OFF the power and use non-conductive gloves such as rubber gloves during the process. 

*Touching the probe with hand directly may cause a failure due to static electricity charge in a human body. 

● 

MAINTENANCE:  When  you  clean  the  probe,  be  sure  to  turn  OFF  the  power,  put  on  non-conductive 
gloves such as rubber gloves to clean the probe with moist cloth.*Touching the probe with hand directly 
may cause a failure due to static electricity charge in a human body.Cleaning the probe with dry cloth may 
also cause a failure due to friction charge generated between the cloth and probe. 

          IMPORTANT 

(indicates notes or information to help customers.) 

Limitations of Warranty: 

  Warranty period shall be one year from the date of delivery (ex-factory).   
  Any damage of any other products that have occurred for use of the equipment is not covered by   

this warranty.    Also any loss induced by failure or malfunction of the equipment is not covered by   
this warranty. 

  Failure or malfunction caused by following are not covered by this warranty: 

a.  Modification or repair by a party other than MATSUSHIMA’s authorized personnel,   

or replacement of parts not recommended by MATSUSHIMA. 

b.  Inadequate storage, installation, use, inspection or maintenance that does not comply   

with specifications. 

c.  Cause for any peripheral equipment or device. 
d.  Accident beyond control and force majeure (fire, earthquake, flood, riots, etc.). 

Lack of instructions to MATSUSHIMA for information or safety requirements that can be predicted only   
by customers’ side. 
This warranty conditions do not limit customers’ legal right. 
Price for the equipment does not include any charge for services such as commissioning,   
supervising, etc.. 

!

!

!

Содержание PFM-KCU11

Страница 1: ...e 11 10 Trouble shooting 12 13 INSTRUCTION MANUAL FOR Dust Monitor TYPE PFM KCU11 Transducer PFM M11P Sensor PFM M11PT High temperature type 1 8 18 Norimatsu Higashi Yahatanishi ku Kitakyushu 807 0837 Japan Phone No 8193 691 3731 Fax No 8193 691 3735 http www matsushima m tech com E mail sales matsushima m tech com The operator should read this Instruction Manual carefully and handle the device co...

Страница 2: ...y long wire Tighten the cover lead outlet etc properly so that dust rainwater etc do not enter inside the equipment Do not use the equipment under a corrosive condition NH3 SO2 CI2 etc Be sure to tighten the cable grand so that outer air does not enter inside the equipment When applying piping connection such as conduit etc instead of cable grand apply putty or equivalents on the cable entry so th...

Страница 3: ...ry under that environment As to considering density regarding to Dust Monitor of Friction Electric Charge Mechanism it requires you to consider influence due to variation of particle characteristics as afore mentioned and it does not always meet density specified Density indicated on specification is for design development of machinery and is publicized for you customers to use as a guideline in d...

Страница 4: ...rature 20 65 Transducer 50 1 2 8 2 Humidity 95 RH Condition State of case sealing up 2 9 Keeping condition 2 9 1 Temperature 20 65 2 9 2 Humidity 95 RH 2 10 Output signal 2 10 1 Current output DC 4 20mA isolated output load resistance 500Ω max 23 3mA 2 10 2 Contact output Alarm contact output 1 250VAC 2A 30VDC 2A Upper limit contact limit output 2 250VAC 2A 30VDC 2A 2 11 Fitting method R1 fit scre...

Страница 5: ...US316L 3 Radiation fin Alminium φ98 30 85 Lead outlet G1 2 6 Transducer PFM KCU11 Sensor PFM M11PT 1 Please detach A between socket and insulator 10mm or more 2 Refer to the specifications for length L1 L2 3 The probe should be touched directly by hand without grounding while being energized 4 Please be sure to connect earth terminal 5 Please tighten the Bolt and Nut when you install it 6 Please m...

Страница 6: ...rotection and is not a raincoat Attention Exclusive cable is transmitting very weak signal Cable should be protected with by all means steel made electric wire pipe independently so that inductive noise form ambient area does not bother signal Securely close the lead outlet to prevent outside air from entering in the main unit Do not remove the accessory Silica gel for dehumidification Where using...

Страница 7: ... for Transducer attaching when you remove the attaching screw covers Please loosen these joining screws of the terminal block part with a Phillips driver You can see the terminal block of the Transducer when you remove the main block part from the terminal block part after having loosened these Joining Screws Joining Screws Mtg Hole Mtg Hole Mtg Hole Mtg Hole Fig 7 Joining screws of terminal and m...

Страница 8: ...2 Completion drawing 1 85 3 5 4 Packing 1 Please pass Cap Clamping member and Rubber bush through the cable Please peel off the cable covering from the verge by the length of 85mm 2 Please make the shield line asunder Please wrap an asunder shield line as shown in left figure 3 Please pass Shield ring through the cable Please peel off the cover of the core wire by 5mm Please use solderless termina...

Страница 9: ...ER LED Light on as power on FAULT LED CPU on when abnormal L1 ON LED Light on over limit1set L2 ON LED Light on over limit1set 4 beams indicate LED detection density will indicate per 0 100 complying with setup for button use when changing beam of number value use when increasing number value MOD use when switching parameter set mode and measure mode Pushing after set change will memorize paramete...

Страница 10: ...output due to its output linear Reference Talc Talc is non organic powder made from ore called Talc being crushed into gray white particle and smooth powder Talc with its chemical name hydrous magnesium silicate Mg3Si4O10 OH containing main ingredient of SiO2 approx 60 MgO approx 30 and combined water of 4 88 As its physical nature Talc of true specific gravity 2 7 2 8 is a substance having lowest...

Страница 11: ...Customers expertise respectively Limit 1 2 and action chart of trouble alarm Limit output upper limit alarm Power OFF to open COM NO Trouble alarm Power OFF to close COM NO 20mA 4mA Time Range to set cang Limit set value ON Limit set value OFF Hysteresis Trouble Device normal Device normal COM NO close LED On COM NO open LED Off COM NO open LED Off COM NO close LED on COM NO open LED off COM NO op...

Страница 12: ... above instead of MOD you push SEL and can perform both setting parameter and moving to plural items at the same time Reference Parameter and light up of corresponding LED RANGE only RANGE LED light up L1 ON only L1 ON LED light up L1 OFF only L1 OFF LED light up L2 ON only L2 ON LED light up L2 OFF only L2 OFF LED light up INTEGRATION TIME only INTEGRATION TIME LED light up 9 Maintenance Measure ...

Страница 13: ...ng is wrong rewire correctly Remove Sensor and check if any sticking on Probe electrode If yes power off and wipe them off with moist cloth See NOTE Remove Sensor and check if Probe electrode has dew condensation If yes power off and wipe it off with moist cloth See NOTE Check if an applicable amount is flowing If necessary change the measurement range and integral setting Output indication goes o...

Страница 14: ...ength and check if they are not in contact If yes change electrode length See NOTE Consult with Sales Dept to check the soundness of Device Power OFF then ON Fault LED is lighted Wiring is wrong The supplied power supply is out of allowable range CPU abnormal Check wiring of power output signal lines exclusive cable See Page 6 5 How to connect If wiring is wrong rewire correctly Check power supply...