11
Technical data
Technical Data Sheet - Indirect storage tank - ErP data
Directive: 2010/30/EU
Regulation: EU 812/2013
Directive: 2009/125/EU
Regulation: EU 814/2013
Water heater Efficiency according to standard: prEN50440 : 2015
M.T. ITEM No.
MODEL/IDENTIFIER
Rating ErP
Heat loss - W
Storage vol.
80341850
PAW-TD 20 C1E5-UK - 1,5kW / 1x230V
A
43
192
80341950
PAW-TD 30 C1E5-UK - 1,5kW / 1x230V
A
49
284
80341951
PAW-TD 30 C1E5HI-UK - 1,5kW / 1x230V
A
49
280
These products are manufactured by OSO Hotwater AS, Industriveien 1, 3300 Hokksund, Norway.
Description
Unit
PAW-
TD20C1E5-UK
PAW-
TD30C1E5-UK
PAW-
TD30C1E5HI-UK
Actual capacity of the water tank at 20°C
L.
192
284
280
Outer diameter of the tank
mm
595
595
595
Height of the appliance
mm
1270
1750
1750
Gross weight of the appliance
kg
50
61
65
Net weight of appliance once filled with sanitary water
kg
241
341
345
Material of element
-
incoloy 825
incoloy 825
incoloy 825
Thermal insulation material
-
PUR+VIP
PUR+VIP
PUR+VIP
Thermal insulation of the tank, average thickness
mm
50
50
50
IP classification
-
21
21
21
Standby heat losses / 24 hour
kWh/24h
1.03
1.18
1.18
Standby heat losses
Watts
43
49
49
V40 Hotwater volume
L.
315
465
389
Primary flowrate for Reheat time & Primary heating power
l/h
900
900
900
Heating coil HEX surface
m²
1.8
1.8
2.35
Heating up time heating coil
min
18.5
26.08
18.5
Primary Heating power heating coil
kW
35
32
39.4
Primary Heating coil pressure drop
mbar
120
120
170
Heat up time immersion heater
min
255
464
384
ErP class
-
A
A
A
Pressure information
Design pressure of cylinder (rated pressure)
MPa/Bar
1 / 10
1 / 10
1 / 10
Design pressure of heating coil
MPa/Bar
1 / 10
1 / 10
1 / 10
Operating pressure of cylinder
MPa/Bar
0.3 / 3
0.3 / 3
0.3 / 3
Operating pressure of heating coil
MPa/Bar
0.25 / 2.5
0.25 / 2.5
0.25 / 2.5
Max. operating temperature of cylinder
°C
70
70
70
Max. operating temperature of heating coil
°C
99
99
99
Hydraulic connections
Secondary return
Inch
3/4”
3/4”
3/4”
Primary Heating coil Flow
Inch
3/4”
3/4”
3/4”
Primary Heating coil Return
Inch
3/4”
3/4”
3/4”
Cold water
Inch
3/4”
3/4”
3/4”
Hot water
Inch
3/4”
3/4”
3/4”
Immersion heater
Inch
5/4”
5/4”
5/4”
T&P valve (factory fitted)
Inch
1/2”
1/2”
1/2”
Temperature sensor sleeve diameter
mm
8
8
8
Electrical characteristics
Supply voltage and frequency
WHz
220-240 VAC
220-240 VAC
220-240 VAC
Power of the electrical resistance
kW
1.5kW@230V
1.5kW@230V
1.5kW@230V
Electrical installation
-
IEEE regs
IEEE regs
IEEE regs
Thermostat type - immersion/cylinder
-
Probe/Probe
Probe/Probe
Probe/Probe
Immersian Heater - Phase
Phase
single
single
single
Immersion thermostat - temp range
°C
8-70
8-70
8-70
Immersion thermostat - set temp
°C
60
60
60
Safety
Safety valve opening pr/- 5%
MPa/Bar
0.8 / 8
0.8 / 8
0.8 / 8
T&P valve opening pressure/Temp.
MPa(Bar) /°C
1/90 (10/90)
1/90 (10/90)
1/90 (10/90)
Safety thermostat cutout - immersion
°C
87
87
87
Safety thermostat cutout - cylinder
°C
80
80
80
Содержание PAW-TD20C1E5-UK