3.6.3.
LSU Image Side to Side Adjustment for the ADU
1. Insert Letter or A4 size paper into the 1st tray and change the tray setting to the appropriate paper
size. Empty all the remaining trays (including the bypass tray) to disable them.
2. Press “
FUNCTION
”, “
ORIGINAL SIZE
” keys and then Key “
3
” on the keypad sequentially.
3. Perform the Service Mode F1-06 (Print Test Pattern 4).
4. Check the gap of the print pattern from the paper edge, refer to the Figure above.
5. Perform the Service Mode F6-16 (ADU Side Adjust), to adjust the gap to be 5 mm.
6. If the gap is less than 5 mm, input a (+) value. If more than 5 mm, input a (-) value.
7. Press "
STOP
" first and then press "
FUNCTION
" + "
CLEAR
" keys simultaneously to return to
standby.
3.6.4.
Original Registration & CCD Read Adjustments
1. Place the Original Document on the Platen Scanner.
2. Insert Letter or A4 size paper into the 1st tray and change the tray setting to the appropriate paper
size. Empty all the remaining trays (including the bypass tray) to disable them.
3. Press “
FUNCTION
”, “
ORIGINAL SIZE
” keys and then Key “
3
” on the keypad sequentially.
4. Perform the Service Mode F2 (Single Copy Test).
5. Check the Image size of the Copy and the Original as Portrait.
6. Perform the Service Mode F6-03 (Original Registration), to adjust the Original Registration.
7. If the gap is smaller than the Original, input a (-) value. If bigger than the Original, input a (+) value.
8. Perform the Service Mode F6-53 (CCD Read Position), to adjust the CCD Read for the side
position.
9. If the gap is smaller than the Original, input a (+) value. If bigger than the Original, input a (-) value.
10. Press "
STOP
" first and then press "
FUNCTION
" + "
CLEAR
" keys simultaneously to return to
standby.
3.6.5.
ADF Original Read Edge & ADF Main Scan Adjustments
1. Place the Original Document on the ADF.
2. Insert Letter or A4 size paper into the 1st tray and change the tray setting to the appropriate paper
size. Empty all the remaining trays (including the bypass tray) to disable them.
3. Press “
FUNCTION
”, “
ORIGINAL SIZE
” keys and then Key “
3
” on the keypad sequentially.
4. Perform the Service Mode F2 (Single Copy Test).
5. Check the Image size of the Copy and the Original as Portrait.
6. Perform the Service Mode F6-91 (Original Read Edge ADF), to adjust the ADF Original Read Edge.
7. If the gap is less than the Original, input a (+) value. If bigger than the Original, input a (-) value.
8. Perform the Service Mode F6-90 (ADF Image Read Start), to adjust the ADF Main Scan for Side
position.
9. If the gap is less than the Original, input a (+) value. If bigger than the Original, input a (-) value.
10. Press "
STOP
" first and then press "
FUNCTION
" + "
CLEAR
" keys simultaneously to return to
standby.
Содержание Panafax UF-9000
Страница 50: ...50 UF 9000 APR 2006 Ver 3 0 DP 180 190 21 Remove the LCD Module 127...
Страница 74: ...74 UF 9000 APR 2006 Ver 3 0 DP 180 190 3 3 Preventive Maintenance Points...
Страница 126: ...126 UF 9000 APR 2006 Ver 3 0 DP 180 190 Sensor and Switch Location...
Страница 196: ...196 UF 9000 APR 2006 Ver 3 0 DP 180 190 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path...
Страница 341: ...341 UF 9000 APR 2006 Ver 3 0 DP 180 190 memo...
Страница 343: ...343 APR 2006 Ver 3 0 UF 9000 DP 180 190 memo...
Страница 344: ...DZSD001829 13 88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3...
Страница 359: ...Published in Japan...
Страница 360: ...DZSD000965 16 Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3...
Страница 371: ...Local Firmware Update Tool Parallel USB Port Page 12 5b4 Firmware Code File selection is completed Click Next...
Страница 375: ...Published in Japan...