Record mode
76
LSQT1135
ª
To restore to automatic adjustment
Set the [AUTO/MANUAL/FOCUS] switch to
[AUTO].
Manual shutter speed adjustment
≥
Avoid recording under fluorescent light, mercury
light or sodium light because the colour and
brightness of the playback image may change.
≥
If you increase the shutter speed manually, the
sensitivity lowers and accordingly the gain value
increases automatically, which may increase
the noises on the screen.
≥
You may see vertical lines of light in the
playback image of a brightly shining subject or
highly reflective subject, but this is not a
malfunction.
≥
During normal playback, image movement may
not look smooth.
≥
When recording in the extremely bright place,
the colour of the screen may change or flickers.
If so, adjust the shutter speed manually to 1/50
or 1/100.
Manual iris/gain adjustment
≥
Set the shutter speed before setting the
aperture (iris/gain) when manually adjusting
both settings.
≥
If the value does not become “OPEN”, you
cannot adjust the gain value.
≥
If the gain value is increased, the noise on the
screen increases.
≥
Depending on the zoom magnification, there are
iris values that are not displayed.
ª
Shutter speed range
1/50 to 1/8000 seconds: Tape Recording Mode
The shutter speed closer to 1/8000 is faster.
ª
Iris/gain value range
CLOSE (Closed), F16, ..., F2.0,
OPEN (Opened: F1.8) 0dB, ..., 18dB
Value closer to [CLOSE] darken the image.
Value closer to [18dB] brighten the image.
Values with dB are gain values.
LSQT1135ENG.book 76 ページ 2006年12月22日 金曜日 午後10時2分