3
Remove power plug
Before repair
Make sure to cut off the power line before disassembly, parts replacement and assembly.
Otherwise, electrical shock or injury may occur.
Electric shock hazard
Be careful of electrical shocks
Be careful of electric shock from live parts or electrical lead terminals when conducting voltage measurement and
other electrical servicing.
Voltage of the control board is approximately 280V when power is ON.
Do not touch live parts.
When replacing parts, do not touch live parts for at least 3 minutes after disconnecting the plug the power supply.
(A little time is required for electrical discharge of the condenser)
Use only fuses specified
When replacing fuses, use only specified in the circuit diagram. The use of nonspecific fuses may cause fire or
malfunction.
Punch the pipes of the faulty compressor securely.
Otherwise, the refrigerant remaining in the compressor oil might leak out during transporting and could catch fire
and explode.
Discharge refrigerant completely from the used service can for disposal in an outdoor place where there is no
fire source.
Otherwise, you could run the risk of fire/explosion.
Prohibited
Do not damage the refrigeration circuit (piping) of the refrigerator.
As the refrigerant is flammable, any damage could lead to fire/explosion.
If the refrigeration circuit is damaged, do not touch the refrigerator or use a naked flame. Open windows for
Ventilation.
As the refrigerant is flammable, any damage could lead to fire/explosion.
Disposal of a faulty compressor must be performed outdoors where there is no fire source.
The quantity of refrigerant in a service can carried in the vehicle must be the least possible, and below the
[regulation][regulated] limit. Keep the service can upright and below 40
°
C. (Quantity on board: 1.5kg or
below)
Use a designated part
Make sure to use a designated part when the part is marked(
) in circuit diagrams and parts lists.
Otherwise,smoke,fire or failure may occur.
Always conduct a safety inspection after completing service
And check the parts are reassembled correctly. Also confirm other fixings and wiring, for deterioration. Replace as
required. Always use a megohmmeter to measure the insulating resistance between both terminals of the power
plug and the earth terminal, and plug the power supply in after first confirming 1M
Ω
or above.
When setting, check that the power cord or power plug is not jammed or pushed against the rear of the refrigera-
tor.
If the power cord or the power plug is damaged or loose, take appropriate measures such as replacing.
If the pins of the plug or the area the pins attach to are dirty, make sure they are cleaned thoroughly.
Содержание NR-B32FX3
Страница 6: ...6 3 General Introduction 3 1 Flow of Refrigerant And Air ...
Страница 7: ...7 4 Features 4 1 Features 4 1 1 High Efficiency Cabinet ...
Страница 8: ...8 4 1 2 Storage Solution ...
Страница 9: ...9 4 1 3 Refrigerator Compartment 4 1 4 Hygiene Active and Multi Airflow ...
Страница 10: ...10 4 1 5 Vegetable Case 4 1 6 Vitamin Safe ...
Страница 11: ...11 4 1 7 Hygiene Active ...
Страница 18: ...18 6 2 Components ...
Страница 19: ...19 7 Installation Instructions 7 1 Installation Instructions ...
Страница 20: ...20 ...
Страница 21: ...21 7 2 Setting the temperature ...
Страница 22: ...22 7 3 Using the handy functions ...
Страница 27: ...27 10 Troubleshooting Guide 10 1 FC and PC not cooling at all Compressor does not run ...
Страница 28: ...28 10 2 PC is not cooling or poor cooling FC cooling condition is normal ...
Страница 29: ...29 10 3 FC is poor cooling Compressor run ...
Страница 30: ...30 10 4 VC is poor cooling or excessive cooling ...
Страница 48: ...48 12 Maintenance ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 51: ...51 13 Dimensions 13 1 Outside ...
Страница 52: ...52 13 2 Inside ...