40
11.7. Disassembly of Compressor
Room
11.7.1. Pan Water EVA., Motor Protector,
Cluster Block
1. Pan Water EVA
a. Pull Power Supply Cord out.
b. Remove the six screws on Cover Panel Compressor.
c. Pull and remove Cover Panel Compressor toward you
from upper side.
d. Pull Pan Water EVA. toward you while pressing it up.
NOTICE
• When you install Cover Panel Compressor, set the holes
of the six screws.
• Adjust its position, and tighten the six screws.
2. Motor Protector
a. Insert a screwdriver (-) into the gap between Protector
Cover and Compressor like the figure.
Pry off Protector Cover in a screwdriver (-).
Remove Protector Cover.
b. Take Motor Protector out from inside Protector Cover.
3. Cluster Block
a. Pull Cluster Block out from Compressor like the figure.
NOTICE
• Be careful not to twist when you pull Cluster Block out or
install.
Содержание NR-B32FX3
Страница 6: ...6 3 General Introduction 3 1 Flow of Refrigerant And Air ...
Страница 7: ...7 4 Features 4 1 Features 4 1 1 High Efficiency Cabinet ...
Страница 8: ...8 4 1 2 Storage Solution ...
Страница 9: ...9 4 1 3 Refrigerator Compartment 4 1 4 Hygiene Active and Multi Airflow ...
Страница 10: ...10 4 1 5 Vegetable Case 4 1 6 Vitamin Safe ...
Страница 11: ...11 4 1 7 Hygiene Active ...
Страница 18: ...18 6 2 Components ...
Страница 19: ...19 7 Installation Instructions 7 1 Installation Instructions ...
Страница 20: ...20 ...
Страница 21: ...21 7 2 Setting the temperature ...
Страница 22: ...22 7 3 Using the handy functions ...
Страница 27: ...27 10 Troubleshooting Guide 10 1 FC and PC not cooling at all Compressor does not run ...
Страница 28: ...28 10 2 PC is not cooling or poor cooling FC cooling condition is normal ...
Страница 29: ...29 10 3 FC is poor cooling Compressor run ...
Страница 30: ...30 10 4 VC is poor cooling or excessive cooling ...
Страница 48: ...48 12 Maintenance ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 51: ...51 13 Dimensions 13 1 Outside ...
Страница 52: ...52 13 2 Inside ...