43
6.3.
Procedure
Procedure of Test Program (for models controlling water filling by flowmeter)
No.
Display on the screen
Process
Description
0
8:88
Initialization
Power on, standby mode.
1
05 or Turbidity value
Inlet Valve
Open inlet valve and fill with 3.6L water. The diverter would move to position rotating
both upper and lower sprayarms. If the model is equipped with turbidity sensor,
turbidity value would be adjusted and shown on the screen.
2
04/Temperature value
Higher-speed
Washing Pump
and Heating Element
Run higher-speed washing pump and 10s later run heating element until water
temperature reaches 57°C. Then the machine will pause.
Press Start/Pause button to jump into the next step.
3
03
Lower-speed
Washing Pump
and Dispenser
2s later run lower-speed washing pump for 8s. dispenser will act for 45s in this step.
4
02
Regeneration Valve
Open regeneration valve for 30s.
5
01
Drain Pump
Drain for 30s.
6
F*
finish
Buzz one sound, stop, and stand by.
Содержание NP-6F2MUQNZ-NZ
Страница 11: ...11 4 Block Diagram 4 1 Water Circuit ...
Страница 13: ...13 5 Troubleshooting 5 1 Location ...
Страница 33: ...33 5 13 Inspection 5 13 1 E1 tree ...
Страница 34: ...34 5 13 2 E3 tree ...
Страница 35: ...35 5 13 3 E4 tree ...
Страница 37: ...37 5 14 Troubleshooting ...
Страница 38: ...38 ...
Страница 39: ...39 ...
Страница 40: ...40 ...
Страница 41: ...41 ...
Страница 44: ...44 7 Exploded View 112 111 107 109 106 108 101 115 104 105 102 103 110 104 113 114 ...
Страница 45: ...45 201 202 203 204 207 210 203 209 208 217 218 220 221 219 214 212 213 211 216 216 326 326 ...
Страница 48: ...48 501 505 510 511 512 513 ...
Страница 49: ...49 601 604 605 606 607 609 610 611 612 614 618 624 625 628 629 630 631 632 ...
Страница 50: ...50 701 705 709 711 ...
Страница 51: ...51 P1 P2 P3 P5 P4 ...