17
5.3.
Inlet valve
5.3.1.
Working Principle
The inlet valve is electromagnetic valve that decide whether water enter or not. Valves are normally closed. Each time the appliance
requires water, the controller will convey an electric signal to the coils to open the valves.
The inlet valve consist of electric coil, valve body, valve pole, filter etc.
In a word, the electromagnetic valve can act to allow water enter into machine, when it receive the order given by controller.
5.3.2.
Possible cause of Malfunction
1. The valve coil is broken, so the valve can’t open. It will cause the E1 error.
2. The filter is jammed, so water can’t enter. It will cause the E1 error.
3. The connector is loose, so the valve can’t open. It will cause the E1 error.
4. The valve pole is rusted or locked by dreg, so the valve can’t open or close. It will cause the E1 or E4 error.
5.3.3.
Technical data
Nominal voltage
220-240VAC
Frequency
50/60Hz
Resistance
Approx: 3.4 - 4.4k
Ω
Work duty
100%ED T25
3min/5min T60
Flux
2.5L/min 15%
Power
5W
Work Pressure
0.04 - 1MPa
Содержание NP-6F2MUQNZ-NZ
Страница 11: ...11 4 Block Diagram 4 1 Water Circuit ...
Страница 13: ...13 5 Troubleshooting 5 1 Location ...
Страница 33: ...33 5 13 Inspection 5 13 1 E1 tree ...
Страница 34: ...34 5 13 2 E3 tree ...
Страница 35: ...35 5 13 3 E4 tree ...
Страница 37: ...37 5 14 Troubleshooting ...
Страница 38: ...38 ...
Страница 39: ...39 ...
Страница 40: ...40 ...
Страница 41: ...41 ...
Страница 44: ...44 7 Exploded View 112 111 107 109 106 108 101 115 104 105 102 103 110 104 113 114 ...
Страница 45: ...45 201 202 203 204 207 210 203 209 208 217 218 220 221 219 214 212 213 211 216 216 326 326 ...
Страница 48: ...48 501 505 510 511 512 513 ...
Страница 49: ...49 601 604 605 606 607 609 610 611 612 614 618 624 625 628 629 630 631 632 ...
Страница 50: ...50 701 705 709 711 ...
Страница 51: ...51 P1 P2 P3 P5 P4 ...