5.4.4.
Inspect drain pump
5.4.4.1.
Check the electric part
1. Open the protecting box and take out the PCB.
2. With the door closed,unplug the CON3 and ACN wires, then use the multi-meter
Ω
shelf to measure the red wire (PS) and
blue wire (ACN), the normal resistance is about 150
Ω
to 190
Ω
.
3. If the measured resistance is not correct, it means the pump coil is broken or connector is loose. In this case, we should check
the connection first. If the problem hasn’t been solved by re-connection, we should replace the drain pump.
4. If the resistance is OK, but it also can’t work, maybe the magnetism is too weak, so we need to replace the drain pump.
5.4.4.2.
Check the machine part
1. If the electric part is OK, we need to check the machine part.
2. Remove bottom board.
3. If the non-return valve is wrongly assembled, the tub will remain much water. We need to re-assemble the non-return valve.
4. If the drain pump is working, but no water drain out or just a little. We should check the drain hose or drain body.
Содержание NP-6F2MUQNZ-NZ
Страница 11: ...11 4 Block Diagram 4 1 Water Circuit ...
Страница 13: ...13 5 Troubleshooting 5 1 Location ...
Страница 33: ...33 5 13 Inspection 5 13 1 E1 tree ...
Страница 34: ...34 5 13 2 E3 tree ...
Страница 35: ...35 5 13 3 E4 tree ...
Страница 37: ...37 5 14 Troubleshooting ...
Страница 38: ...38 ...
Страница 39: ...39 ...
Страница 40: ...40 ...
Страница 41: ...41 ...
Страница 44: ...44 7 Exploded View 112 111 107 109 106 108 101 115 104 105 102 103 110 104 113 114 ...
Страница 45: ...45 201 202 203 204 207 210 203 209 208 217 218 220 221 219 214 212 213 211 216 216 326 326 ...
Страница 48: ...48 501 505 510 511 512 513 ...
Страница 49: ...49 601 604 605 606 607 609 610 611 612 614 618 624 625 628 629 630 631 632 ...
Страница 50: ...50 701 705 709 711 ...
Страница 51: ...51 P1 P2 P3 P5 P4 ...