- 65 -
Important
information
* ) Status LED indicator (STATUS) and alarm code LED indicator (ALM CODE) start flashing
simultaneously.
Protection
Error counter
over flow
* EEPROM
parameter
error
* EEPROM
check code
error
Overttravel
inhibit
* Other error
Alarm
CodeNo.
2 9
3 6
3 7
3 8
9 9
*
C o u n t e r m e a s u r e s
Check that the motor operates per the
position command pulse. See the torque
monitor to check that the output torque
does not get saturated. Readjust the gains.
Maximize the value of Pr5E (torque limit set-
up). Correct the encoder wiring.
Set all the parameters again. If this error
occurs frequently, the amplifier may have
been broken. Replace the amplifier with a
new one. Return the old amplifier to the
sales agent for repair.
T h e a m p l i f i e r m a y h a v e b e e n b r o k e n .
Replace the amplifier with a new one. Return
the old amplifier to the sales agent for repair.
C h e c k t h e s w i t c h e s , w i r e s a n d p o w e r
supply that constitute the circuits. Check
that the control power (12 to 24VDC) can
be established without delay. Check the
v a l u e o f P r 0 4 . C o r r e c t t h e w i r i n g , i f
necessary.
Turn off the power and turn it on again. If
the error cannot be eliminated, the motor
a n d / o r a m p l i f i e r m a y b e b r o k e n .
Discontinue use of the motor, and replace
the motor and the amplifier. Return the old
equipment to the sales agent for repair.
C a u s e
The value of the position error counter is
o v e r 2
2 7
( 1 3 4 2 1 7 7 2 8 ) .
The data contained in the parameter stor-
age area of the EEPROM is broken,
The check code of the EEPROM is bro-
ken,
Both the CW and CCW over-travel limits
are not active.
The control circuit operates incorrectly
due to large noises or any other reasons.
The amplifier's self-diagnosing function is
activated, because an error happens in
the amplifier.
Status LED
red
red
orange
orange
Alarm code LED
red
orange
red
orange