‑ 17 ‑
Parameter Setting
Setting
Operation Panel
Frequency Hz is displayed when in the normal monitor mode.
You can display synchronized rotations for the parameter "
display power."
5-digit LED
Displays output frequency, set frequency or display power, cause of error, or
parameter.
2-digit LED
Displays parameter No. Direction of rotation is displayed in the monitor mode.
MODE
switch
Switch for changing monitor mode. Pressing the switch changes the mode in the
cycle of:
Output frequency
Converter voltage
Motor current
Switch for selecting parameter No. mode and parameter value mode, setting
parameter value.
DATA SET
switch
●
Mode description
△
▽
switch
Enable you to select parameters, and set/change contents.
RUN switch
Commands the inverter to run.
STOP
switch
Commands the inverter to stop.
Monitor
mode
Displays output frequency, converter voltage or motor current.
Mode when the power is turned on.
When in the parameter No. mode or parameter value mode,
pressing the MODE switch changes to the monitor mode.
Parameter
No. mode
Displays parameter No.
(
〜
)
by flashing.
When in the monitor mode, pressing the DATA SET switch
changes to the parameter No. mode.
Parameter
value mode
Displays parameter contents (setting value)
by flashing.
You can change the setting value with the
△
▽
switches.
After changing the setting, press the DATA SET switch to
enter the setting in the memory.
r/min
Hz
A
V
STOP
DATA
SET
RUN
MODE
^^
5-digit LED
2-digit LED