‑ 15 ‑
(2) Control terminal
<Terminal screw size: M2, Tightening torque 0.25 ~ 0.3 N·m>
Terminal No. Terminal name
Function description
5V
Power source
terminal for fre-
quency setting
+ 5VDC applied. I max. = 20 mA
12V
Power source
terminal for
input terminal
+ 12VDC applied. I max. = 20 mA
FI
Input terminal
for frequency
setting
Frequency can be set when 0 ~ +5VDC (or 0 - +10VDC) is input
between “FIN1” and “G.”
If using these terminals, change “
frequency command” to
−
or
−
.
G
Ground for
control
Common ground terminal for contact input.
FOUT
Frequency
meter terminal
Outputs voltage proportional to output frequency between “FOUT” and
“G.” Connect full-scale 1 mA DC ammeter. You can output pulses
synchronized with output frequency by altering “
FOUT switch”.
I1
Forward/stop
command
terminal
I2
Reverse /stop
command
terminal
Forward by shorting between “I1” and “G”; stop by release
Reverse by shorting between “I2” and “G”; stop by release
You can change “I1” to run/stop command and “I2” to forward/reverse
command by altering“
I1.12” function selection.
I3
I4
I5
Frequency
setting
selection
terminal
You can select the following functions by "
operation mode selection."
Input
t
e
rmina
l
G
Ground for
control
Contact input common ground terminal.
O1
C1
Output signal
terminal
Open-collector output terminal. (Not maintained when power is OFF.)
You can select contents by “
output signal (1) selection.”
Factory setting: “01” is trip signal (transistor ON when tripped)
“O1” (collector) IC max. = 50mA
“C1” (emitter) VCE max. = 24VDC
Ou
tp
u
t te
rmi
n
a
l
NC
NO
C2
Output signal
terminal
Relay output terminal. 30VDC 1A (max.)
(Not maintained when power is OFF.)
You can select output contents by “
relay output polarity selection.”
Not built-in to products without regenerative brake circuit.
NO
NC
01
FI
FO
I1
I3
I5
C2
C1
5V
G
12V
I2
I4
G
Operation mode
I3
I4
I5
2-speed
operation mode
Forward
jogging
Reverse
jogging
4-speed
operation mode
8-speed
operation mode