‑ 11 ‑
Installation
Install the inverter properly to prevent equipment failure or accidents.
Inverter
Installation location
①
Install the inverter indoors in a place not exposed to rain or direct sunlight. The inverter
is not waterproof.
②
Install in a place not exposed to corrosive/flammable gases, grinding fluid, oil mist, metal
powder or chips.
③
Place with adequate ventilation, which is not exposed to excessive humidity, dirt or dust.
④
Place not subject to vibration.
Environmental conditions
Item
Conditions
Ambient temperature
−
10
〜
50
℃
(Must not freeze)
Single-phase input specifications:
−
10 to 40
℃
Ambient humidity
Max. 90%RH
(
Must be no condensation
)
Storage temperature
−
20
℃
〜
65
℃
(Must not freeze)
Storage humidity
Max. 90 %RH
(
Must be no condensation
)
Protection structure
IP40
(
Built-in the panel
)
Vibration
Max. 5.9 m/s
2
(
10
〜
60
H
z
)
Elevation
Max. 1000 m
* Short-term temperature during transport
Mounting direction and clearance
・
Provide sufficient clearance for effective cooling.
Make sure ambient temperature doesn’t exceed allowable temperature at position indicated
by X in the figure above.
Inverter
Min.
50 mm
30 mm
×
×
30 mm
Min. 100 mm
Min.
10 mm
Min.
10 mm
Min.
50 mm
Min.
50 mm
30 mm
×
Inverter
Inverter