Panasonic M1S Series Скачать руководство пользователя страница 1

For speed control of 3-phase induction motor

Low-Noise Inverter M1S Series

Operating Instructions

Be sure to provide the customer with a copy of this manual.

Thank you for purchasing a Panasonic Inverter.

Be sure to read the instructions thoroughly before attempting to operate the
inverter. After reading, be sure to keep in a safe place for future reference.

Industrial and Appliance Motor Division, Motor Company

Matsushita Electric Industrial Co., Ltd

Содержание M1S Series

Страница 1: ...stomer with a copy of this manual Thank you for purchasing a Panasonic Inverter Be sure to read the instructions thoroughly before attempting to operate the inverter After reading be sure to keep in a safe place for future reference Industrial and Appliance Motor Division Motor Company Matsushita Electric Industrial Co Ltd ...

Страница 2: ... Wiring general view 12 Applicable peripheral 13 equipment Wiring 14 Terminal function 14 Precautions when wiring 16 Protective Functions 2 6 Protective functions 26 Method of resetting trip 28 Detalied Explanation 3 1 of Parameters Specifications 4 5 Before use Preparation and adjustment If necessary Application and Specifications ...

Страница 3: ... Selection of operation 20 Parameter configuration 17 commands and list of parameters How to change operation 20 Setting 17 command Operation function 20 Test Operation 19 Pre operation inspections 19 Test operation 19 Maintenance 29 Servicing Backcover Inspection Troubleshooting 30 Outer Dimensions 46 Parameter Setting 47 Before use If necessary Preparation and Adjustment Application and Spec ...

Страница 4: ...ected with core serious consequences depending upon the circumstances In any case these instructions are extremely important and should be observed in all cases Installation CAUTION Install on non combustible material such as metal Failure to do so could result in fire Do not locate near combustibles Doing so could result in fire Do not carry by the front case when moving the inverter Doing so is ...

Страница 5: ...trical shock or fire Have wiring work done a licensed electrician Failure to do so could result in electrical shock or fire Be sure to install the inverter before wiring Failure to do so could result in electrical shock or fire CAUTION Do not ground the AC power source with the output terminals U T1 V T2 W T3 Doing so could result in injury or fire Make sure the voltage of the AC power source agre...

Страница 6: ... running Doing so could result in electric shock If the retry function is selected the inverter could unexpectedly start operating again if tripped Do not approach the inverter in the condition Doing so could result in injury If trip reset is carried out with the operate signal ON the inverter could unexpectedly start operating again Do not approach the inverter in the condition Doing so could res...

Страница 7: ...ion Use only insulated tools when performing maintenance or inspection Failure to do so could result in electric shock or injury Other DANGER Absolutely DO NOT modify the inverter in any way Doing so could result in electric shock injury or fire GENERAL PRECAUTIONS The diagrams given in this instruction manual may show the cases covers or safety breakers removed in order to show details When opera...

Страница 8: ...V Single phase 200 V 3 phase 200 V Code Interface specs A B C D Without communication function standard type NPN logic Without communication function standard type PNP logic With communication function standard type NPN logic With communication function standard type NPN logic Code Operation panel specs S V N Without volume standard With volume Blank cover Code Regenerative brake specs A C Without...

Страница 9: ... static electricity when wiring After wiring always replace the case and the operation panel to their original positions Panasonic Panasonic Panasonic Panasonic Operation panel Case GND terminal GND terminal Operation panel fixing screws Volume is mounted for the products with volume Operation panel connector Case fixing screw Charge lamp DC reactor terminal Power terminals Regenerative brake resi...

Страница 10: ...ded on the power source on and off 4 Operating the motor by the inverter could increase leakage current and trip the earth leakage breaker In this case use earth leakage breakers designed for high frequency for this system and other systems 5 Take the following precautions if using a built in electronic thermal relay contained in the inverter Check the rated current of your 3 phase induction motor...

Страница 11: ...em Conditions Ambient temperature 10 50 Must not freeze Single phase input specifications 10 to 40 Ambient humidity Max 90 RH Must be no condensation Storage temperature 20 65 Must not freeze Storage humidity Max 90 RH Must be no condensation Protection structure IP40 Built in the panel Vibration Max 5 9 m s2 10 60Hz Elevation Max 1000 m Short term temperature during transport Mounting direction a...

Страница 12: ...ter Noise filter NF Blocks noise from the power line Also reduces effect of noise from the servomotor Magnetic contactor MC Turn main power to servomotor on off Used with surge absorber mounted AC reactor AC L Reduces harmonic current of the power source Refer to Option DC reactor DC L Reduces harmonic current of the power source Refer to Option Regenerative resistor Improves regenerative control ...

Страница 13: ... BBP35 5A BMFT61842N 3P 1a BMF902E 0 95 1 45A 2 0 AWG14 0 75 AWG18 MIS04 2 3 0 4 BBP35 5A BMFT61842N 3P 1a BMF904E 1 7 2 6A 2 0 AWG14 0 75 AWG18 MIS08 2 3 0 75 BBP310 10A BMFT61842N 3P 1a BMF907E 2 8 4 2A 2 0 AWG14 0 75 AWG18 Use the same size of wire for GND terminal as the wire for main circuit 2 Relay selection For relays used in control circuits such as the control input terminal you should us...

Страница 14: ...5 P PB Regenerative resistor terminal Regenerative resistor connection terminal M2 5 0 3 0 5 T L3 S L2 R L1 External frequency setting volume 1 4W 5kΩ B characteristic Frequency meter 1mA full scale FOUT G FIN1 5V E C1 O1 W T3 V T2 U T1 Emitter VCE max DC24V IC max 50mA Trip signal Contact capacity DC30V 1A Frame ground Collector trip output IM Motor Short direct current reactor connection termina...

Страница 15: ...elease Reverse by shorting between I2 and G stop by release You can change I1 to run stop command and I2 to forward reverse command by altering I1 12 function selection I3 I4 I5 Frequency setting selection terminal You can select the following functions by operation mode selection Input terminal G Ground for control Contact input common ground terminal O1 C1 Output signal terminal Open collector o...

Страница 16: ... short the wire could be pulled Twist the bare wires when wiring so that they will not get loose 2 Use a wire which diameter is less than 0 9 mm when wiring using a bar terminal or single wire If it is larger than 0 9 mm the screw thread may be damaged when tightened 3 Do not apply more than 24VDC 50mA to the output terminals O1 C1 or apply voltage to terminal in reverse 4 Input terminal configura...

Страница 17: ...A SET switch Mode description switch Enable you to select parameters and set change contents RUN switch Commands the inverter to run STOP switch Commands the inverter to stop Monitor mode Displays output frequency converter voltage or motor current Mode when the power is turned on When in the parameter No mode or parameter value mode pressing the MODE switch changes to the monitor mode Parameter N...

Страница 18: ...and DOWN keys MODE DATA SET DATA SET Storage Storage Parameter value display LED will flash Data will be stored every time UP key or DATA SET key is pressed in the parameter value mode Change select parameter values with UP and DOWN keys Output frequency MODE Current MODE Converter voltage Parameter value mode Can set directly No 0 speed setting with UP and DOWN keys Parameter No mode ...

Страница 19: ...cedures shown below Operation panel Operation Switch LED display Remarks Turn on the power Turn ON the power in the monitor mode Output frequency is displayed When setting with the volume on the operation panel set frequency command selection to Volume See page 21 Operation panel Operation Switch LED display Remarks Frequency setting Press Press to set frequency No 0 speed frequency is displayed O...

Страница 20: ...y set values How to change operation command Ex Change frequency command selection to from Operation panel Operation Switch LED display Turn on the power Parameter No mode Press DATA SET Press and select the parameter No Press and select the parameter No Parameter value mode Press DATA SET Store the setting with MODE or DATA SET Press and select the parameter No 1 When the operation command is set...