Necessary items (not supplied):
ü
Telephone cable for extension connection:
Diameter of cable
(ø 0.4 mm to ø 0.6 mm)
Maximum length of cable
ø 0.5 mm
1128 m for SLT
ø 0.5 mm
720 m for KX-DT300/KX-T7600 series
ø 0.5 mm
229 m for other DPT, APT and DSS Console
The maximum length of the cable may vary depending on the type of cable and installation conditions.
ü
An RS-232C cross cable or Ethernet straight cable for PC connection
ü
Connectors (Amphenol/RJ45/BNC) for trunk and extension connections
Note
•
The Ethernet straight cable should be a 10BASE-T/100BASE-TX CAT 5 (Category 5) or higher cable.
•
Use a shielded twisted pair cable for the Amphenol connector.
•
Use a twisted pair cable for the RJ45 connector.
Getting Started for Physical Cards
7
1.3 Unpacking
WWW.ERTEBATGROUP.COM
WWW.ERTEBATGROUP.COM