SLT Off Hook Guard Time
Specifies the length of time used to prevent the PBX from mistaking an off-hook signal as a pulse dial.
Default
504 ms
Value Range
8 × n (n=12–63) ms
Programming References
Feature Guide References
None
SLT Pulse Maximum Break Width
Specifies the maximum length of the break signal in a pulse dial.
Default
96 ms
Value Range
8 × n (n=9–20) ms
Programming References
Feature Guide References
None
SLT Pulse Minimum Make Width
Specifies the minimum length of the make signal in a pulse dial.
Default
8 ms
Value Range
8 × n (n=1–5) ms