4.6 Help
Feature Guide
309
Q
How do I prevent extension numbers being automatically assigned to a newly
installed card?
A
•
Change
in the
Configuration—Option
screen (see
"4.7.10 Option [1-3]") from
Automatic
to
Manual
.
Q
How do I prevent newly installed cards automatically being changed to "INS"?
A
•
Change
in the
Configuration—Option
screen (see "4.7.10
Option [1-3]") from "In Service (INS)" to "Out of Service (OUS)".
Q
I cannot change an LCO port to INS status.
A
•
Is the card installed in the appropriate slot?
•
Is the card installed in the correct slot, but not functioning correctly?
Check the condition of the card.
•
Is the card itself in INS status?
Set it to INS status.
•
Is a CO line connected to the appropriate port?
•
Is the port in FAULT status, even though a CO line is connected?
Run diagnosis on the relevant slot.
Q
How do I change the dialing mode of an analog CO line?
A
•
From the
Configuration—LCO Port
screen (see "4.7.11 LCO Port [1-4]"), change the
setting of the target port to "DTMF" or "Pulse", as required.
Q
How do I set disconnect detection (CPC Detection) for an analog CO line?
A
•
From the
Configuration—LCO Port
screen (see "4.7.11 LCO Port [1-4]"), modify the
CPC Signal Detection Time—Outgoing, Incoming
setting of the target port.
The required value varies by carrier. Transmission and reception can be set separately.
Q
I cannot open the subwindow for a certain card.
A
•
First, either install the card, or set the status of a slot to "Pre-Install".
Q
How do I change the extension number of a wired extension?
A
•
Change the extension number of the target port to the new number, and click
Apply
.
Then set the port to OUS status, and then back to INS status.
Q
During a conversation, I changed the extension number of a wired extension,
but the display still shows the previous extension number.
A
•
The extension number will not change while the extension is in use. When the
conversation is finished, set the port to OUS status, and then back to INS status.
Q
How do I change the type of an extension port?
A
•
Set the port to OUS status. Then, change
Type
in the
Configuration—Extension Port
window (see "4.7.13 Extension Port [1-5]").
Q
I have set the type of an extension port to "DSS Console", but I cannot apply
this setting. (Error E000402)
Содержание KX-TDA50
Страница 16: ...16 Feature Guide...
Страница 17: ...Feature Guide 17 Section 1 Call Handling Features...
Страница 67: ...1 5 Making Call Features Feature Guide 67 User Manual References 1 2 1 Basic Calling...
Страница 215: ...Feature Guide 215 Section 2 System Configuration and Administration Features...
Страница 244: ...2 4 Fault Recovery Diagnostics 244 Feature Guide...
Страница 245: ...Feature Guide 245 Section 3 Programming Instructions...
Страница 281: ...Feature Guide 281 Section 4 KX TDA50 Maintenance Console Operating Instructions...
Страница 446: ...4 8 System 2 446 Feature Guide Feature Guide References 1 16 1 Caller ID...
Страница 621: ...4 14 ARS 8 Feature Guide 621 Feature Guide References 1 9 1 Automatic Route Selection ARS...
Страница 652: ...4 17 Maintenance 11 652 Feature Guide...
Страница 653: ...Feature Guide 653 Section 5 Appendix...
Страница 661: ...Feature Guide 661 Index...