2.3 System Data Control
232
Feature Guide
2.
Connection Methods for Remote Programming
Conditions
•
Only one system programming session is permitted at a time. Access will be denied when a second
party tries to perform system programming, including system programming via a PT.
•
Programmer Code and Password for System Programming
To access system programming, a programmer code and its password must be entered. For more
details, see Section 3.1 Introduction.
•
Remote Programming Limitation
It is possible to disable remote access through system programming (
→
Disabling this feature will also disable the ability to perform on-site programming via modem.
•
If an extension user sets Walking Extension at the same time that the extension's data is being
programmed through PC programming, the data may not be transferred properly. (
→
Method
Description
Required
Hardware
Off-site modem
Call the PBX and have the call directed to the floating
extension number assigned to the analog remote maintenance
feature (
→
Modem Floating Extension Number [811]) using
one of the following methods:
Direct Access:
Using the off-site modem, dial a telephone
number with the modem which will direct your call (via Direct
In Line [DIL] distribution) to the floating extension number
assigned to the analog remote maintenance feature.
DISA:
Using a telephone, dial a telephone number which will
direct your call (via DIL distribution) to a floating extension
number used by the Direct Inward System Access (DISA)
feature (
→
1.15.6 Direct Inward System Access (DISA)). Next,
dial the floating extension number assigned to the analog
remote maintenance feature. Then access the PBX with the
modem.
Call Transfer:
Using a telephone, dial a telephone number
which will direct your call to an operator (or other extension of
the PBX) and request to be transferred to the floating
extension number assigned to the analog remote maintenance
feature. (
→
1.11.1 Call Transfer) Then access the PBX with the
modem.
RMT card and
user-supplied
modem
On-site modem
The modem is connected to the Serial Interface (RS-232C
port) and also to either an extension port which is assigned as
the DIL destination, or to a CO line directly. AT commands can
be sent to the modem automatically when it is connected to the
Serial Interface (RS-232C port) and can be programmed
beforehand, through system programming, to initialize the
modem. AT commands can also be sent manually in the PT
system programming mode (
→
User-supplied
modem
Содержание KX-TDA50
Страница 16: ...16 Feature Guide...
Страница 17: ...Feature Guide 17 Section 1 Call Handling Features...
Страница 67: ...1 5 Making Call Features Feature Guide 67 User Manual References 1 2 1 Basic Calling...
Страница 215: ...Feature Guide 215 Section 2 System Configuration and Administration Features...
Страница 244: ...2 4 Fault Recovery Diagnostics 244 Feature Guide...
Страница 245: ...Feature Guide 245 Section 3 Programming Instructions...
Страница 281: ...Feature Guide 281 Section 4 KX TDA50 Maintenance Console Operating Instructions...
Страница 446: ...4 8 System 2 446 Feature Guide Feature Guide References 1 16 1 Caller ID...
Страница 621: ...4 14 ARS 8 Feature Guide 621 Feature Guide References 1 9 1 Automatic Route Selection ARS...
Страница 652: ...4 17 Maintenance 11 652 Feature Guide...
Страница 653: ...Feature Guide 653 Section 5 Appendix...
Страница 661: ...Feature Guide 661 Index...
Страница 667: ...Index Feature Guide 667...