Address
Default
Name
Country
Setting
Type
Description
0467
00
Factory Language
Setting
06
D
Factory setting for language:
00 = English
01 = Spanish
02 = French
03 = Italian
04 = Dutch
05 = Turkish
06 = Hungarian
07 = Portuguese
08 = Polish
09 = Command
0A = German
28.3.3. Battery Parameters
Address
Default
Name
Type
Description
0F04
9A
LowVoltage
A
Voltage on which to start battery low
indication.
The voltage has to be measured under
value for
8 seconds before the handset start
signaling low battery.
LowVoltage[eeprom]=[ADC-steps]
LowVoltage[mV](14.35[mV/step])
28.3.4. Default Audio-Parameters