Items
Adjustment
Point
Procedure*
Check
(D)
Charge Control
Check & Charge
Current Monitor
Confirmation
-
1. Apply 6V between TP5(+) and TP6(-) with current limit of PSU to 200mA.
2. Confirm that the charge current is ON/OFF.
3. SW to decrease current limit of PSU to 100mA.
4. Confirm that the charge current is stable.
IC1,D4,L4,
L5,Q2,Q3,
R6,D2,R22,
C26,F1,R21,
(E)
*
Charge Detection
(OFF)
Confirmation
-
1. Stop supplying 6V to TP5(+) and TP6(-).
2. Execute the command "charge".
3. Confirm that the returned value is 0x00 (hex).
IC1,D4,L4,
L5,Q2,Q3,
R6,D2,R22,
C26,F1,R21,
(F)
*
Battery Monitor
Confirmation
-
1. Apply 2.3V ± 0.005V between TP3(+) and TP4(-).
2. Execute the command "readbatt".
3. Confirm:
98 < returned value < A8 (Hex)
4. Execute the command "WRTBAT2 XX".
XX: (returned value) - 06 (Hex)
IC1,D4,L4,
L5,Q2,Q3,
R6,D2,R22,
C26,F1,R21,
(G)
Battery low
Confirmation
-
1. Apply 2.40V between TP3(+) and TP4(-).
2. Confirm that there is no Speaker sound (Battery low alarm).
3. Apply 2.20V between TP3(+) and TP4(-).
4. Confirm that there is Speaker sound (Battery low alarm).
IC1,F1,R21,
R4,C33,C12,
C31,R17,R20,
C10,C11,D6,
(H)
*
BBIC Clock
Adjusment
TP19
1. Execute the command "conttx".
2. Adjust the frequency of TP19 executing thecommand "setfreq 00 xx (where xx is the
value)" so that the reading of the frequency counter is 10.368000MHz ± 3Hz.
IC1,L3,C57,
IC3,X1,C16,
48
Содержание KX-TCD400HGB
Страница 23: ...Shown in Fig To Remove Remove 1 Lower Cabinet Screws 2 6 12 A 2 2 Main P C Board Main P C Board 9 2 Handset 23...
Страница 53: ...19 FREQUENCY TABLE MHz 53...
Страница 59: ...The BBIC detects this level and power down 24 SIGNAL ROUTE 25 CPU DATA BASE UNIT 25 1 IC2 BBIC 59...
Страница 63: ...45 MICP A I 63...
Страница 74: ...74...
Страница 75: ...31 CABINET AND ELECTRICAL PARTS LOCATION HANDSET 32 ACCESSORIES AND PACKING MATERIALS 75...
Страница 76: ...33 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 33 1 Base Unit 33 2 Handset 76...