Items
Adjustment
Point
Procedure*
Check
(I)*
Transmitted
Power
Confirmation
TP15
Remove the Antenna before starting step from 1 to 5.
1. Configure the DECT tester(CMD60) as follows;
<Setting>
-Test mode: PP
-RFPI: 0102030405
-Traffic Channel: 5
-Traffic Slot: 4
-Mode: Loopback
2. Execute the command "testmode".
3. Execute the command "regcmd60"
4. Initiate connection from DECT tester.
5. Confirm that the NTP value at A201 (TP15) is 20dBm ~ 25dBm
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
(J)
Modulatoin
Check and
Adjusment
TP15
Follow steps 1 to 4 of (I) above.
5. Confirm that the B-Field Modulation is 340kHz/div ~ 402kHz/
div using data type Fig31.
6. Adjust the B-Field Modulation if required. (Execute the
command "Readmod" and "Writemod xx", where xx is the
value.)
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
(K) Frequency Offset
Confirmation
-
Follow steps 1 to 4 of (I) above.
5. Confirm that the frequency offset is < ± 40kHz.
IC1,IC3,C54,
C66,C60,L3,
C57,C55,C56,
C62,R23,R24,
C63,C64,C65,
49
Содержание KX-TCD400HGB
Страница 23: ...Shown in Fig To Remove Remove 1 Lower Cabinet Screws 2 6 12 A 2 2 Main P C Board Main P C Board 9 2 Handset 23...
Страница 53: ...19 FREQUENCY TABLE MHz 53...
Страница 59: ...The BBIC detects this level and power down 24 SIGNAL ROUTE 25 CPU DATA BASE UNIT 25 1 IC2 BBIC 59...
Страница 63: ...45 MICP A I 63...
Страница 74: ...74...
Страница 75: ...31 CABINET AND ELECTRICAL PARTS LOCATION HANDSET 32 ACCESSORIES AND PACKING MATERIALS 75...
Страница 76: ...33 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 33 1 Base Unit 33 2 Handset 76...