1.17 T
204
Feature Manual
Exception Code Tables
Exception Code Tables are preprogrammed lists of leading digits or complete telephone numbers which are
checked against every dialed number prohibited by a Denied Code Table. When a user dials a number
prohibited by a Denied Code Table, it is compared to at least one Exception Code Table. If the dialed number
matches an entry found in the applicable Exception Code Table, the call is permitted.
There are five Exception Code Tables. Each table applies to a corresponding TRS level as well as the
level(s) preceding it, as explained below.
TRS Override by System Speed Dialing
When TRS Override by System Speed Dialing is enabled for the PBX, each COS has an additional TRS
level applicable only to calls made using System Speed Dialing.
→
2.8.11 [2-7-1] Class of Service—COS Settings—TRS—TRS Level for System Speed Dialing
→
[300] TRS Override by System Speed Dialing
This allows extension users to use System Speed Dialing to make CO line calls which are normally
prohibited by the TRS level of their assigned COS. If, for example, a user's TRS level is 7, that user normally
cannot make any CO line calls. However, if the same user's TRS level for System Speed Dialing is level 1,
the user can make a CO line call to any number stored in System Speed Dialing.
TRS Level
The TRS level is determined by the telephone codes set in the Denied Code Tables and Exception Code
Tables.
As shown in the table below, the Denied Code Tables for the higher levels are applied to all levels below it,
and the Exception Code Tables for the lower levels are applied to all levels above it.
[Usage Example]
Using this method, certain outgoing CO line calls (e.g., international/cellular phone/long
distance) can be restricted as in the example below:
Denied Code Tables
*1
Exception Code Tables
*2
Level 1
Not Programmable
Not Programmable
Level 2
Table for Level 2
Tables for Levels 2 through 6
Level 3
Tables for Levels 2 and 3
Tables for Levels 3 through 6
Level 4
Tables for Levels 2 through 4
Tables for Levels 4 through 6
Level 5
Tables for Levels 2 through 5
Tables for Levels 5 through 6
Level 6
Tables for Levels 2 through 6
Table for Level 6
Level 7
Not Programmable
Not Programmable
*1
:
→
2.13.1 [7-1] Denied Code—Denied Code Tables—Level 2–Level 6
→
[301] TRS Denied Code
*2
:
→
2.13.2 [7-2] Exception Code—Exception Code Tables—Level 2–Level 6
→
[302] TRS Exception Code
Restricted
Allowed
Level 1
No restriction
Содержание KX- TAW848
Страница 11: ...Feature Manual 11 Section 1 Features and Configurations...
Страница 24: ...1 1 A 24 Feature Manual None Feature Manual References 1 17 3 Timed Reminder...
Страница 52: ...1 3 C 52 Feature Manual 413 LCOT CPC Signal Detection Time Outgoing 414 LCOT CPC Signal Detection Time Incoming...
Страница 100: ...1 6 F 100 Feature Manual Operating Manual References 3 1 2 Personal Programming...
Страница 175: ...1 15 R Feature Manual 175 Feature Manual References 2 1 Capacity of System Resources...
Страница 191: ...1 16 S Feature Manual 191 3 1 2 Personal Programming...
Страница 234: ...1 20 W 234 Feature Manual...
Страница 235: ...Feature Manual 235 Section 2 Appendix...
Страница 244: ...2 3 Revision History 244 Feature Manual...
Страница 245: ...Feature Manual 245 Index...