Explanation:
•
SMDR data is not deleted even if the PBX is reset.
•
If the PBX is reset during a conversation, the call will not be logged by SMDR.
•
The following calls are regarded as two separated calls in the SMDR:
–
Calls before and after the flash/recall/EFA signal is manually sent during a conversation
–
CO-to-CO line calls by Call Transfer, FWD or DISA (each is logged as both an "incoming call" and
an "outgoing call")
•
The PBX waits for a preprogrammed time period after the end of dialing before starting the SMDR timer
for outgoing CO line calls. When the PBX has sent out all dialed digits to the telephone company and
this timer expires, the PBX begins measuring the duration of the call. A display proprietary telephone
(PT) shows the elapsed time of the call. The starting time and the total duration of the call are logged
by SMDR.
→
2.8.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—Dial—Analog CO Call Duration Start
→
[208] Call Duration Count Starting Time for LCOT
•
Serial Interface (RS-232C) Parameters
The following communication parameters can be assigned for the Serial Interface (RS-232C port).
a)
New Line Code:
Select the code appropriate for the PC or printer. If the PC or printer automatically
feeds lines with carriage return, select "
CR
". If not, select "
CR+LF
".
→
2.16.1 [10-1] Main—RS-232C—Communication—NL Code
→
[800] RS-232C Parameter—New Line Code
b)
Baud Rate:
Baud rate indicates the transmission speed of data from the PBX to the PC or printer.
→
2.16.1 [10-1] Main—RS-232C—Communication—Baud Rate
→
[800] RS-232C Parameter—Baud Rate
c)
Word Length:
Word length indicates how many bits compose each character.
→
2.16.1 [10-1] Main—RS-232C—Communication—Word Length
→
[800] RS-232C Parameter—Word Length
d)
Parity Bit:
Parity bit indicates what type of parity is used to detect errors in the string of bits
composing a character. Make an appropriate selection depending on the requirements of the PC
or printer.
→
2.16.1 [10-1] Main—RS-232C—Communication—Parity Bit
→
[800] RS-232C Parameter—Parity Bit
e)
Stop Bit Length:
Stop bit indicates the end of a bit string which composes a character. Select an
appropriate value depending on the requirements of the PC or printer.
→
2.16.1 [10-1] Main—RS-232C—Communication—Stop Bit
→
[800] RS-232C Parameter—Stop Bit Length
•
If a call is transferred to an ICD group using Automatic Transfer, the condition code "TR" will not be
recorded on SMDR (
→
1.3.8 Call Transfer).
Skip
Perforation
Page
Length
Machine
Perforation
Содержание KX- TAW848
Страница 11: ...Feature Manual 11 Section 1 Features and Configurations...
Страница 24: ...1 1 A 24 Feature Manual None Feature Manual References 1 17 3 Timed Reminder...
Страница 52: ...1 3 C 52 Feature Manual 413 LCOT CPC Signal Detection Time Outgoing 414 LCOT CPC Signal Detection Time Incoming...
Страница 100: ...1 6 F 100 Feature Manual Operating Manual References 3 1 2 Personal Programming...
Страница 175: ...1 15 R Feature Manual 175 Feature Manual References 2 1 Capacity of System Resources...
Страница 191: ...1 16 S Feature Manual 191 3 1 2 Personal Programming...
Страница 234: ...1 20 W 234 Feature Manual...
Страница 235: ...Feature Manual 235 Section 2 Appendix...
Страница 244: ...2 3 Revision History 244 Feature Manual...
Страница 245: ...Feature Manual 245 Index...