2.7 [1] Configuration
PC Programming Manual
83
Feature Manual References
1.3.1 Caller ID
Caller ID—Caller ID (FSK) Detection Start Timer
Specifies the length of time that the PBX waits before attempting to detect Caller ID information, after
receiving a call. To enable this setting,
Caller ID—Caller ID Signalling
on this screen should be set
to
FSK
.
Default
80 ms
Value Range
None, 80 × n (n=1–15) ms
Maintenance Console Location
2.7.7 [1-1] Slot—LCO Card Property
Programming Manual References
None
Feature Manual References
1.3.1 Caller ID
Caller ID—Caller ID (FSK) Detection Timer
Specifies the total time required by the PBX to detect Caller ID information. To enable this setting,
Caller ID—Caller ID Signalling
on this screen should be set to
FSK
.
Default
2000 ms
Value Range
80 × n (n=13–50) ms
Maintenance Console Location
2.7.7 [1-1] Slot—LCO Card Property
Programming Manual References
None
Feature Manual References
1.3.1 Caller ID