2.11 [5] Optional Device
380
PC Programming Manual
Value Range
100 + 10 × n (n=1–390) ms
Maintenance Console Location
2.11.3 [5-3-1] Voice Message—DISA System
Programming Manual References
2.7.1 [1-1] Slot
Feature Manual References
None
DISA Cyclic Tone Option—Tone Off Maximum Time
Specifies the maximum time that the PBX waits for a cyclic tone to be sent from the telephone
company before recognising it as a tone-off. When no tone is detected within the time set here, the
PBX recognizes it as a tone-off.
Note that this option can only be set when
DISA Cyclic Tone Detection
on this screen is set to
"Option".
To apply changes to this setting, follow the steps below:
1.
Change this setting.
2.
Set the status of the MSG2 card to "
OUS
", then "
INS
".
Default
600 ms
Value Range
100 + 10 × n (n=1–390) ms
Maintenance Console Location
2.11.3 [5-3-1] Voice Message—DISA System
Programming Manual References
2.7.1 [1-1] Slot
Feature Manual References
None
DISA Cyclic Tone Option—Repeating Times of On/Off for Detection
Specifies the number of times the tone pattern (a set of tone-on and tone-off) must be received to
establish reception of the cyclic tone. This determines the end of call.
Note that this option can only be set when
DISA Cyclic Tone Detection
on this screen is set to
"Option".
Default
3
Содержание KX- TAW848
Страница 8: ...8 PC Programming Manual...
Страница 9: ...PC Programming Manual 9 Section 1 Overview This section provides an overview of programming the PBX...
Страница 11: ...1 1 Introduction PC Programming Manual 11...
Страница 16: ...1 2 PC Programming 16 PC Programming Manual...
Страница 448: ...2 16 10 Maintenance 448 PC Programming Manual...
Страница 449: ...PC Programming Manual 449 Section 3 Appendix...