2.9 [3] Group
204
PC Programming Manual
Maintenance Console Location
2.9.3 [3-2] Extension Group
Programming Manual References
2.9.4 [3-3] Call Pickup Group
2.9.6 [3-4] Paging Group
2.10.1 [4-1-1] Wired Extension—Extension Settings—Main—Extension Group
2.10.8 [4-2-1] Portable Station—Extension Settings—Main—Extension Group
Feature Manual References
1.7.1 GROUP FEATURES
Tenant Number
Specifies the tenant to which the extension user group belongs.
Default
1
Value Range
1–8
Maintenance Console Location
2.9.3 [3-2] Extension Group
Programming Manual References
2.8.5 [2-4] Week Table
Feature Manual References
1.7.1 GROUP FEATURES
1.17.2 Tenant Service
2.9.4
[3-3] Call Pickup Group
Extensions can be assigned to a call pickup group according to their extension user groups. One
extension user group can belong to up to 8 call pickup groups. A maximum of 64 call pickup groups
can be programmed.
To assign extension user groups to call pickup groups easily, click
All Setting
.
Extension Group Name
Indicates the name of the extension user group (reference only).
Default
Extension User Group 1–32: Extension Group 01–32