2.9 [3] Group
220
PC Programming Manual
Group Name
Specifies the name of the incoming call distribution group.
Default
ICD Group 001–ICD Group 128
Value Range
Max. 20 characters
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
None
Extension No Answer Redirection Time
Specifies the length of time that a call queues at an extension before it is redirected to the next
member extension of the incoming call distribution group, in UCD or Priority Hunting distribution
method.
Default
None
Value Range
None, 10 × n (n=1–15) s
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
1.9.2 ICD Group Features—Group Call Distribution
1.9.5 ICD Group Features—Queuing
No. of Unanswered Calls for Automatic Log-out
Specifies the number of consecutive unanswered calls before a member extension is automatically
logged out from the incoming call distribution group.
Default
None