2.7 Connection of DECT Portable Stations
86
Installation Manual
•
The CS should not be placed on a metal object.
•
Do not use this wireless system near another high power cordless system such as
DECT or SS wireless.
•
Keep distance between the equipment listed below in order to prevent noise,
interference or the disconnection of a conversation. (The distance may vary
depending on the environment.)
Equipment
Distance
CS and office equipment such as a computer, telex,
fax machine, etc., or microwaves
More than 2 m
CS and PS
More than 1 m
Each PS
More than 0.5 m
Hybrid IP-PBX and CS
More than 2 m
Too many CSs in a small area can cause problems due to conflicts over which signal
channels each CS can use. Ideally, CSs should be a minimum of 25 m to 40 m apart.
However, the required distance between CSs may vary depending on the
environment of the installation site and conditions in which the wireless system is
used. Conduct the site survey to determine the appropriate distance.