100
KX-FT932BR-B
12.5.5. Digital Board Section
When the unit fails to boot up the system, take the troubleshooting procedures very carefully. It may have a serious problem.
The symptom: No response when the power is turned on. (No LCD display, and keys are not accepted.)
The first step is to check the power source. If there is no problem with the power supply unit, the problem may lie in the digital
unit (main board).
As there are many potential causes in this case (ASIC, DRAM, etc.), it may be difficult to specify what you should check first. If
a mistake is made in the order of checks, a normal part may be determined faulty, wasting both time and money.
Although the tendency is to regard the problem as a serious one (IC malfunction, etc.), usually most cases are caused by solder
faults (poor contact due to a tunnel in the solder, signal short circuit due to solder waste).
Note:
1. Electrical continuity may have existed at the factory check, but a faulty contact occurred as a result of vibration, etc., during
transport.
2. Solder waste remaining on the board may get caught under the IC during transport, causing a short circuit.
Before we begin mass production, several hundred trial units are produced at the plant, various tests are applied and any mal-
functions are analyzed. (In past experiences, digital IC (especially DRAM and FLASH ROM) malfunctions are extremely rare
after installation in the product.)
This may be repaired by replacing the IC, (DRAM etc.). However, the real cause may not have been an IC malfunction but a sol-
dering fault instead.
Soldering faults difficult to detect with the naked eye are common, particularly for ASIC and RA (Resistor Array). But if you have
an oscilloscope, you can easily determine the problem site or IC malfunction by checking the main signal lines.
Even if you don’t have such a measuring instrument, by checking each main signal line and resoldering it, in many cases the
problem will be resolved.
An explanation of the main signals (for booting up the unit) is presented below.
Don’t replace ICs or stop repairing until checking the signal lines.
An IC malfunction rarely occurs. (By understanding the necessary signals for booting up the unit, the “Not Boot up”
display is not a serious problem.)
What are the main signals for booting up the unit?
The ASIC (IC1) controls all the other digital ICs. When the power is turned on, the ASIC retrieves the operation code stored in
the FLASH ROM (IC2), then follows the instructions for controlling each IC. All ICs have some inner registers that are assigned
to a certain address.
It is the address bus by which the ASIC designates the location inside each IC. And the data bus reads or writes the data in
order to transmit the instructions from the ASIC to the ICs.
These signal lines are all controlled by voltages of 3.3V (H) or 0V (L).
Содержание KX-FT932BR-B
Страница 11: ...11 KX FT932BR B 6 Technical Descriptions 6 1 Connection Diagram ...
Страница 21: ...21 KX FT932BR B 6 4 2 Block Diagram ...
Страница 23: ...23 KX FT932BR B ...
Страница 35: ...35 KX FT932BR B b Redundancy Compression Process Coding Mode This unit uses one dimensional MH format ...
Страница 60: ...60 KX FT932BR B 11 2 The Example of the Printed List 11 2 1 User Mode Example of a printed out list ...
Страница 61: ...61 KX FT932BR B 11 2 2 Service Mode Example of a printed out list ...
Страница 67: ...67 KX FT932BR B ...
Страница 68: ...68 KX FT932BR B CROSS REFERENCE Test Mode P 54 ...
Страница 69: ...69 KX FT932BR B CROSS REFERENCE Test Mode P 54 ...
Страница 70: ...70 KX FT932BR B CROSS REFERENCE Test Mode P 54 ...
Страница 71: ...71 KX FT932BR B ...
Страница 73: ...73 KX FT932BR B ...
Страница 74: ...74 KX FT932BR B ...
Страница 75: ...75 KX FT932BR B CROSS REFERENCE Test Mode P 54 ...
Страница 102: ...102 KX FT932BR B NG Wave pattern Note Refer to NG Example P 107 ...
Страница 104: ...104 KX FT932BR B I O and Pin No Diagram ...
Страница 106: ...106 KX FT932BR B ...
Страница 107: ...107 KX FT932BR B 12 5 5 3 NG Example ...
Страница 111: ...111 KX FT932BR B 12 5 7 2 Troubleshooting Flow Chart ...
Страница 115: ...115 KX FT932BR B 12 5 10 CIS Contact Image Sensor Section Refer to Scanning Block P 24 CROSS REFERENCE Test Mode P 54 ...
Страница 116: ...116 KX FT932BR B 12 5 11 Thermal Head Section Refer to Thermal Head P 22 ...
Страница 117: ...117 KX FT932BR B 13 Service Fixture Tools ...
Страница 120: ...120 KX FT932BR B 14 2 Disassembly Procedurel 14 2 1 How to Remove the Operation Panel Block ...
Страница 121: ...121 KX FT932BR B 14 2 2 How to Remove the Operation Board LCD and Platen Roller ...
Страница 122: ...122 KX FT932BR B 14 2 3 How to Remove the Separation Holder and Document Feed Support ...
Страница 123: ...123 KX FT932BR B 14 2 4 How to Remove the Image Sensor CIS and Feed Roller ...
Страница 124: ...124 KX FT932BR B 14 2 5 How to Remove the Lock Lever and Thermal Head ...
Страница 125: ...125 KX FT932BR B 14 2 6 How to Remove the Bottom Frame ...
Страница 126: ...126 KX FT932BR B 14 2 7 How to Remove the Analog Board Digital Board Power Supply Board and Power Cord ...
Страница 127: ...127 KX FT932BR B 14 2 8 How to Remove the Gear Block and Separation Roller 14 2 9 How to Remove the Motor of Gear Block ...
Страница 128: ...128 KX FT932BR B 14 2 10 Installation Position of the Lead Wires ...
Страница 134: ...134 KX FT932BR B 15 2 3 Mechanical Movements in the Main Operations 15 2 3 1 Idle Status ...
Страница 136: ...136 KX FT932BR B 15 2 3 4 Copying CROSS REFERENCE Sensor Section P 114 ...
Страница 140: ...140 KX FT932BR B 16 1 4 Power Supply Board ...
Страница 143: ...143 KX FT932BR B 16 3 Test Chart 16 3 1 ITU T No 1 Test Chart ...
Страница 144: ...144 KX FT932BR B 16 3 2 ITU T No 2 Test Chart ...
Страница 145: ...145 KX FT932BR B MEMO ...
Страница 152: ...152 KX FT932BR B MEMO ...
Страница 161: ...161 KX FT932BR B MEMO ...
Страница 163: ...163 KX FT932BR B 20 1 2 Upper Cabinet Section ...
Страница 164: ...164 KX FT932BR B 20 1 3 Lower Cabinet Section ...
Страница 165: ...165 KX FT932BR B 20 1 4 Gear Block Section ...
Страница 166: ...166 KX FT932BR B 20 1 5 Screws ...
Страница 167: ...167 KX FT932BR B 20 1 6 Accessories and Packing Materials ...