KW8M Eco-POWER METER
3
Chapter 2 Parts Name and Working
2.1 Parts Names
①
Display indicator
・
Lighting or Blinking according to the display
②
LOCK indicator
・
Lighting while in lock mode
③
T/R indicator
・
Blinking while communication
④
OUT indicator
・
Lighting when pulse output
⑤
Display each value
・
Display each measured value
・
Display each setting value
⑥
MODE Key
⑦
SET Key
⑧
ITEM /
△
Key
⑨
SHIFT /
▽
Key
⑩
Left / Right ( / ) Keys
⑪
OPTION Key
⑫
START/STOP Key
2.2 Select Keys’ Functions
Key
Functions
<MODE>
・
Use to select mode
<SET>
・
Use to set each value entered
<
ITEM
△
>
・
To select measured display
・
To shift each mode
・
To change each setting value
<
SHIFT
▽
>
・
To select measured display
・
To shift each mode
・
To change each setting value
< Left / Right ( / )>
・
To change each setting value
<SET> + <MODE>
・
To reset the measured value
<SET>
・
All keys locked
・
Release lock mode while in lock mode
(continuous press 3-sec)
<OPTION>
・
To shift power monitoring mode and option mode (Only AKW8111H)
<START/STOP>
・
To start and stop measuring integral electric power (active)
for arbitrary period. (from press this key until press it again)
(Only AKW8111H)
⑨
⑧
⑪
⑫
⑤
②
③
④
①
⑥
⑦
⑩