5.9.1 Normal Sensing Mode
■
Overview
In this mode, control output ON/OFF is controlled for a single threshold.
You can select the teaching method from either one of the following two types.
Set value
Operation
Reference page
2-point teaching
This method is to perform teaching on the reference plane
of two sensing objects and to set the intermediate value
of the teaching results as the threshold value.
Limit teaching
This method is to perform teaching on the reference plane
of sensing objects and to set the value obtained from
adding the shift value to or subtracting it from the teaching
result as the threshold value.
2-point Teaching
■
Overview
This method is to perform teaching on the reference plane of two sensing objects and to set the
intermediate value of the teaching results as the threshold value.
For setting procedure, refer to
"4.1.3 2-point Teaching (Normal Sensing Mode)"
.
Limit Teaching
■
Overview
This method is to perform teaching on the reference plane of sensing objects and to set the
value obtained from adding the shift value to or subtracting it from the teaching result as the
threshold value. This is a convenient teaching method for minute objects or when there is a
background object.
1.
Press the TEACH key when there is a background object or when there is a sensing object.
5.9 Sensing Output Setting (Teaching)
5-18
WUME-HGF1UM-2