3.1.7 Error Codes
The error codes are as follows.
Error codes
For GT01, GT11 and GT21
Error code
Error name
Measures
ER00
BCC error
The value of BCC may be incorrect. Check if there is no
calculation mistake.
ER01
Format error
A command format may be incorrect. Check if it is correct.
ER02
NOT supported error
A command used is not supported with the version of the
GT. Upgrade the version of the GT, or use another
command.
ER03
Address error
The address specified does not exist in the GT. Check the
address of the transmitted command.
ER04
Receive buffer overflow
The sent command exceeds the receivable number of
bytes. Check the number of bytes of the sent command.
ER05
Requested overflow
The sent readout command exceeds the number of bytes
that can send back. Check the number of the read words.
ER06
Data error
The communication condition for the GT may be
unmatched with the condition for a destination device.
Check the communication conditions.
ER07
Data write inhibit error
A command for the address that writingn is not available
was sent. Check the address of the sent command.
For GT02, GT02L, GT05, GT12, GT32 and GT32-E
Error code
Error name
Measures
**0000
BCC error
The value of BCC may be incorrect. Check if there is no
calculation mistake.
**0001
Format error
A command format may be incorrect. Check if it is correct.
**0002
NOT supported error
A command used is not supported with the version of the
GT. Upgrade the version of the GT, or use another
command.
**0003
Address error
The address specified does not exist in the GT. Check the
address of the transmitted command.
**0004
Receive buffer overflow
The sent command exceeds the receivable number of
bytes. Check the number of bytes of the sent command.
**0005
Requested overflow
The sent readout command exceeds the number of bytes
that can send back. Check the number of the read words.
**0006
Data error
The communication condition for the GT may be
unmatched with the condition for a destination device.
Check the communication conditions.
**0007
Data write inhibit error
A command for the address that writingn is not available
was sent. Check the address of the sent command.
Note) These are the error codes related to communicaiton.
3.1.8 Restrictions
Allowable bytes sent and received
The allowable number of bytes to be sent and received in the GT is up to 512 bytes (including CR).
Therefore, a command or response of which size is more than 513 bytes cannot be sent from the
external device.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Содержание GT02
Страница 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 17: ...Chapter 3 Command Response Mode Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 29: ...Chapter 4 Two way 1 Mode Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 42: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 43: ...Chapter 5 Two way 2 Mode Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 58: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 59: ...Chapter 6 Documentation Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Страница 60: ...6 1 ASCII Code Table Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...