PRECAUTIONS

• Do not attempt to disassemble the camera.

To prevent electric shock, do not remove screws or
cover. There are no user-serviceable parts inside.
Refer servicing to qualified service personnel.

• Do not expose the camera or camera control unit to

rain or moisture, or do not try to operate it in wet areas.
Do take immediate action if ever the camera or camera
control unit do become wet. Turn power off and refer
servicing to qualified service personnel.
Moisture can damage the camera and camera control
unit and also create the danger of electric shock.

• Ambient Temperature range

Do not install the camera in the place which is beyond
14 °F - 104 °F (

10°C - +40 °C).

• Do not drop anything inside the camera.

Dropping metal for example inside the camera could
permanently damage the unit.

• Never crush or pinch the camera cable.

Do not bend the camera cable into a curve whose
radius is too small.

• Never face the camera is in use, never face it toward

the sun.

• Never face the camera toward the sun

whether the camera is in use or not, never face it
toward the sun.
Do use caution when operating the camera in the vicin-
ity of spot lights or other lights and light reflecting
objects.

• How to take care of this camera.

After turning OFF the Power ON/OFF Switch, clean it
with a dry cloth. If it is difficult to remove the dirt or
dust, clean it up with a cloth applied the neutral
cleanser.
Use the lens cleaning tissue paper(may be available at
your local camera store) for lens cleaning.

• Connect this to a DC12V, 0.5 A - 0.7 A CLASS 2 Power

supply only.

• After using the camera, turn OFF the power ON/OFF

Switch and put the lens cap on the camera head.

• Every necessary procedures with regard to install this

product should be made by qualified service person-
nel or system installers.

Caution:

Connecting or disconnecting camera cable to/from the
camera control unit must be done after turning OFF the
Power ON/OFF Switch. Otherwise, the camera head may
be damaged.

Содержание GPKS162CUD - CONTROL UNIT

Страница 1: ...Camera Control Unit GP KS162CUD Before attempting to connect or operate this product please read these instructions completely Lens Cable and Camera Head option ...

Страница 2: ...le is intended to alert the user to the pres ence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilat eral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompa nying the ap...

Страница 3: ...hanges are sensed instantly and compensated for by a microcomputer in the GP KS162CU Proper white bal ance is then obtained via the built in Auto Tracing White Balance ATW circuit Both White Balance and R and B color can also be adjusted manually for optimum color reproduction The camera head can be used with most existing camera systems And VTR video printer or floppy disk recorder for a host of ...

Страница 4: ... radius is too small Never face the camera is in use never face it toward the sun Never face the camera toward the sun whether the camera is in use or not never face it toward the sun Do use caution when operating the camera in the vicin ity of spot lights or other lights and light reflecting objects How to take care of this camera After turning OFF the Power ON OFF Switch clean it with a dry clot...

Страница 5: ...7 9 1 2 0 t i 3 1 1 2 3 FOCUS LOCK Panasonic GP KS162H MANU OFF VIDEO LEVEL ON OFF AUTO LIGHT AWC ATW MANU WHITE BAL LEVEL B R AWC SET DC POWER ON OFF CAMERA GP KS162 Optional Camera Cable GP CA162 2 2m GP CA162 3 3m GP CA162 38 3 8m GP CA162 10 10m Camera Control Unit GP KS162CU Optional Camera Head GP KS162H GP KS162 Series Standard Configuration Camera Head Tripod Attachment Camera Control Unit...

Страница 6: ...ed to select the Video Level OFF When this switch is set to the OFF position the video signal is supplied with the standard level MANU When this switch is set to the MANU position the video level is adjustable by means of the Video Level Control 8 Note This switch can be used as the Gain Up Down Switch due to the value set by the Video Level Control 8 8 Video Level Control LEVEL This controls the ...

Страница 7: ...onic shutter mode This switch is used to disable the ELC function Normally turn on this switch 15 AGC On Off Switch When shooting the objects under the low light condi tion the video level can be controlled by the gain of the video amplifier This switch is used to disable the AGC function Normally turn on this switch In the Auto Light On mode the setting mode is differ ent by the combination of EL...

Страница 8: ...y rotating it clockwise slowly GP KS162H with GP AD22TA and optional C mount lens 1 Remove the front cap of the camera head and confirm that the surface of the optical filter of the camera head is clean If the surface of the optical filter is dirty or dusts are on it clean it up with a blower brush which is for film cam era lenses may be available at your local camera store or supplied lens cleani...

Страница 9: ...f Manual Switches White Balance Mode ATW MANU AWC AWC SET SET Auto Light Video Level Off Manual Controls R B gain VIDEO Level Power Source 12V DC 300 mA Camera Cable Length GP CA162 2 Cable 6 6 feet 2 meter GP CA162 3 Cable 9 9 feet 3 meter GP CA162 38 Cable 12 5 feet 3 8 meter GP CA162 10 Cable 33 feet 10 meter Ambient Temperature 14 F 104 F 10 C 50 C Dimensions Camera Head 2 3 Diameter x 1 1 2 D...

Страница 10: ...VISION Executive Office One Panasonic Way 4H 2 Secaucus New Jersey 07094 201 392 6674 MATSUSHITA ELECTRIC OF CANADA LIMITED 5770 Ambler Drive Mississauga Ontario L4W 2T3 Canada 905 624 5010 PANASONIC SALES COMPANY DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO INC San Gabriel Industrial Park 65th Infantry Ave KM 9 5 Carolina Puerto Rico 00630 809 750 4300 ...

Отзывы: