-4-
Camera Control Unit GP-KS162CU
1. DC Power On/Off Switch (DC POWER, ON/OFF)
2. Auto White Balance Control Button (AWC SET)
The white balance can be set by pressing this button
when the White Balance Selection Switch (4) is set to
the AWC position.
3. White Balance Indicator
4. White Balance Selection Switch (WHITE BAL,
AWC/ATW/MANU)
AWC :
The white balance is automatically set and
fixed by detecting the characteristic / color
temperature of light source through the lens
and controlling the gain of red and blue signal.
The White Balance Indicator lights during the
setting.
Note:
When the White Balance Offset On/Off
Switch is turned on, the fine adjustment for
R/B gain is available by means of the R
and B Gain Controls (5) after completing
the white balance setting. The adjustable
range is approx. 2,200K - 10,000K.
ATW :
The white balance is automatically and contin-
uously set by detecting the characteristic /
color temperature of light source through the
lens and controlling the gain of red and blue
signal even if the characteristic / color temper-
ature varies.
Note:
When the White Balance Offset On/Off
Switch is turned on, the fine adjustment for
R/B gain is available by means of the R
and B Gain Controls after completing the
white balance setting. The adjustable
range is approx. 2,300K - 6,000K.
MANU:
The R/B gain of the white balance can be
adjusted manually by means of the R and B
Gain Controls.
The adjustable range of the white balance
temperature is approx. 2,200K - 10,000K.
5. R / B Gain Controls (R/B)
These controls are used to adjust the R and B gain of
the white balance.
6. Auto Light On/Off Switch (AUTO LIGHT ON/OFF)
ON:
When this switch is set to the ON position, the
video signal is set to the best level with the combi-
nation of the Electronic light Control On/Off
Switch(14) and AGC On/Off Switch(15).
7. Video Level Selection Switch (VIDEO LEVEL,
MANU/OFF)
This switch is used to select the Video Level.
OFF:
When this switch is set to the OFF position, the
video signal is supplied with the standard level.
MANU:
When this switch is set to the MANU position,
the video level is adjustable by means of the Video
Level Control (8).
Note:
This switch can be used as the Gain Up/Down
Switch due to the value set by the Video Level
Control (8).
8. Video Level Control (LEVEL)
This controls the video level when the Video Level
Selection Switch (7) is set to the MANU position.
The video level control depends on the Auto Light
On/Off Switch (6) setting as shown below.
AUTO LIGHT OFF :
By turning this counterclockwise, the video level is
decreased.
By turning this clockwise, the video level is
increased.
The video level setting at the center position of this
control is higher than the standard one.
AUTO LIGHT ON :
By turning this counterclockwise, the standard
video level is decreased.
By turning this clockwise, the standard video level
is increased.
The standard video level setting at the center posi-
tion of this control is higher than standard one.
9. Camera Cable Connector (CAMERA)
This 16-pin connector is used for connection of the
optional camera cable.
Caution:
Connecting or disconnecting the camera
cable must be done after turning OFF the Power
ON/OFF Switch.
10. S-Video Output Connector (S-VIDEO OUT)
The luminance (Y) and chroma (C) signals for S-VHS
VCR or monitor are provided at this connector.
Pin Configuration
Caution:
To prevent fire or shock hazard, the UL listed
wire VW-1 style 1007 should be used for the cable
for DC 12V Input Terminal.
11. EVR Adjustment Connector
This connector is used to connect with the EVR.
12. Video Output Connectors (BNC)(VIDEO OUT 1,2)
A 1.0 Vp-p ohms composite video signal is provided at
this connector.
13. DC 12V Input Terminals (DC 12V IN)
These terminals accept an external DC source supply-
ing nominal power of 12V, 0.5A - 0.7A.
CAUTION: CONNECT THIS TO A DC 12V CLASS 2
POWER SUPPLY ONLY.
4
2
3
1
Pin No. Description
1.
Y Ground
2.
C Ground
3.
Y Signal Output: 0.714 Vp-p (Y level/75 ohms)
4.
C Signal Output: 0.286 Vp-p (burst Level/75 ohms)