Press
Press
Press
Ԙ
Press MODE key to light up MODE indicator / TEACH (yellow).
Set to Output 1 ' '.
Turn Jog switch: Select
Press Jog switch: Confirmed
Ԝ
In case stable sensing is possible: '
䇭 䇭 䇭 䇭
' is displayed.
In case stable sensing is not possible: '
䇭 䇭 䇭 䇭
' is displayed.
In case of window comparator mode / 2-level teaching
ԙ
The current teaching method is displayed for 0.5 sec.
Ԛ
Press Jog switch in the object present condition. If the
teaching is accepted, the read incident light intensity blinks in
the digital display.
ԛ
Press Jog switch in the object present condition. If the
teaching is accepted, the read incident light intensity blinks in
the digital display.
٨
This is a method of setting the threshold range by two levels (P-1, P-2) teaching.
1_SL(P-1)
2_SL(P-2)
ԝ
The value of ' ' becomes the threshold value (1_SL), which
is displayed. (Note)
Ԟ
The value of ' ' becomes the threshold value (1_SL), which
is displayed. (Note)
In case the set value exceeds the max. (min.) sensitivity, the set value is fixed at max. (min.) sensitivity.
Note:
٨
٨
٨
The output operation setting can be done when MODE indi-
cator / L/D ON (yellow) lights up.
Turn Jog switch to select either the output 1 ' ' or the
output 2 ' ' and press it to confirm.
The output operation is changed when Jog switch is turned
to the '+' side or the '-' side. When Jog switch is pressed, the threshold value is confirmed.
or
OUTPUT OPERATION SETTING MODE
11
Press
Turn
Confirmed
PRO MODE
13
٨
PRO settings can be done when MODE indicator / PRO
(yellow) lights up.
For details of the settings and the setting procedure of the PRO mode, refer to
'
Panasonic Industrial Devices SUNX website
' or contact our office.
or
TIMER OPERATION SETTING MODE
12
٨
٨
٨
٨
The setting for whether the timer is used or not can be done
when MODE indicator / TIMER (yellow) lights up.
Turn Jog switch to select either the output 1 ' ' or the
output 2 ' ' and press it to confirm.
The initial value of each timer function is 10ms.
Refer to '
PRO MODE / PRO1 mode setting
' for the setting method of the OFF-
delay timer, ON-delay timer, ONE-SHOT timer, ON-delay
OFF-delay timer and
ON-delay
ONE-SHOT timer intervals.
13
<In case of Output 1>
ON-delay
㨯
ONE-SHOT timer
ON-delay
㨯
OFF-delay timer
ONE-SHOT
timer
OFF-delay
timer
ON-delay
timer
Turn
Turn
Turn
Turn
Turn
Turn
(Without timer)
The timer interval set in the PRO mode is displayed.
The factory setting is without timer ' '.
Notes: 1)
2)
Press: Confirmed
<In case of Output 2>
ONE-SHOT
timer
OFF-delay
timer
ON-delay
timer
Turn
Turn
Turn
Turn
(Without timer)
The timer interval set in the PRO mode is displayed.
The factory setting is without timer ' '.
Notes: 1)
2)
Press: Confirmed
PRO1 mode setting
Response time: 150
Ǵ
s or less
High speed
Response time: 250
Ǵ
s or less
Standard
Response time: 700
Ǵ
s or less
Standard 2
Response time: 65
Ǵ
s or less
Ultra high speed
Press
Press
Turn
Response time: 2.5ms or less
Long-range
Response time: 4.5ms or less
Ultra long-range
Turn
Turn
OFF-delay timer
OFF-delay timer
ON-delay timer
ON-delay timer
ON-delay
㨯
OFF-delay timer
ONE-SHOT timer
ONE-SHOT timer
ON-delay
㨯
ONE-SHOT timer
(Note 2)
Press
Press
Press
Press
Turn
Turn
Turn
The range of available timer delays is
0.5ms, 1 to 9999ms (1ms increments).
Turn
Press
Turn
The range of available timer delays is
0.5ms, 1 to 500ms (1ms increments).
Turn
Notes: 2) For OFF-delay, ON-delay or ON-delay
ONE-SHOT timer, follow the procedure giv-
en below for setting.
Press
Press
Press
Press
Without timer
Without timer
Notes: 1) For the incident light intensity display, up to max. 9,999 digit
can be displayed in STDF, LONG or U-LG mode. Up to 4,000
digit is possible in H-SP, FAST or STD mode.
Press
Press
Press
Press
Ԙ
Press MODE key to light up MODE indicator / TEACH (yellow).
Set to Output 1 ' '.
Turn Jog switch: Select
Press Jog switch: Confirmed
ԝ
In case stable sensing is possible: '
䇭 䇭 䇭 䇭
' is displayed.
In case stable sensing is not possible: '
䇭 䇭 䇭 䇭
' is displayed.
In case of window comparator mode / 3-level teaching
ԙ
The current teaching method is displayed for 0.5 sec.
Ԛ
Press Jog switch in the object present condition. If the
teaching is accepted, the read incident light intensity blinks in
the digital display.
Ԝ
Press Jog switch in the object present condition. If the
teaching is accepted, the read incident light intensity blinks in
the digital display.
ԛ
Press Jog switch in the object present condition. If the
teaching is accepted, the read incident light intensity blinks in
the digital display.
٨
٨
This is a method of setting the threshold range by three levels (P-1, P-2, P-3)
teaching and set the threshold values st the middle of 'A' and 'B' (1_SL) and 'B'
and 'C' (2_SL) as per the diagram below.
After teaching, P-1, P-2 and P-3 are automatically assigned in ascending order to
'A', 'B', and 'C'.
Ԟ
The middle of 'A' and 'B' becomes the threshold (1_SL), as
shown in the diagram above, which is displayed. (Note)
ԟ
The middle of 'B' and 'C' becomes the threshold (2_SL), as
shown in the diagram above, which is displayed. (Note)
1_SL
B
C
A
2_SL
In case the set value exceeds the max. (min.) sensitivity, the set value is fixed at max. (min.) sensitivity.
Note:
THRESHOLD VALUE FINE ADJUSTMENT MODE
9
Press
Turn to '-' side.
Turn to '-' side.
Turn to '+' side.
Turn to '+' side.
Confirmed
or
or
Press
In case of the window
comparator mode
٨
٨
٨
٨
Fine adjustment of the threshold value can be done when
MODE indicator / ADJ (yellow) lights up.
Turn Jog switch to select either the output 1 ' ' or the out-
put 2 ' ' and press it to confirm.
In case of the window comparator mode has been set, when
the jog switch is pressed in the output 1 ' ', ' ' or ' '
is displayed. Turn the jog switch to select and press it to confirm.
When Jog switch is turned to the '+' side, the threshold val-
ue increases (sensitivity decreases). When Jog switch is turned to
the '-' side, the threshold value decreases (sensitivity increases).
When Jog switch is pressed, the threshold value is confirmed.
٨
٨
The models listed under “
SPECIFICATIONS
” come with CE Marking.
As for all other models, please contact our office.
Contact for CE
<Until June 30 ,2013>
Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
<From July 1 ,2013>
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
1
INTENDED PRODUCTS FOR CE MARKING
10