For further details on the fiber sensor amplifier, please refer to '

Panasonic 

Industrial Devices SUNX website

'

 

or contact our office.

٨
٨

Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use 
products which meet standards, such as OSHA, ANSI or IEC etc., 
for personnel protection applicable in each region or country.

WARNING

CAUTIONS

3

٨
٨

٨
٨
٨

٨

٨

٨
٨
٨

٨
٨

٨
٨
٨

٨
٨

This product has been developed / produced for industrial use only.
When the emission halt of the emitting power switching function is set from 'OFF' to 'ON', the 
output may be unstable. Do not use the output control for 0.5 sec. after starting emission.
Make sure that the power supply is off while wiring.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if an AC power
supply is directly connected, the sensor may get burnt or damaged.
In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity 
of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
Do not use during the initial transient time (0.5 sec.) after the power supply is switched on.
Take care that short-circuit of the load or wrong wiring may burn or damage the sensor.
Do not run the wires together with high-voltage lines or power lines or put them in 
the same raceway. This can cause malfunction due to induction.
Make sure to use the optional quick-connection cable for the connection of the amplifier.
Extension up to total 100m (if 5 to 8 units are connected in cascade: 50m, if  9 to 16 units are connected 
in cascade: 20m) is possible with 0.3mm

2

, or more, cable. However, in order to reduce noise, make the 

wiring as short as possible. Furthermore, take care that cable extension increases the residual voltage.
This sensor is suitable for indoor use only.
Avoid dust, dirt, and steam.
Take care that the product does not come in contact with water, oil, grease,  organ-
ic solvents, such as, thinner, etc., strong acid or alkaline.
This sensor cannot be used in an environment containing inflammable or explosive gases.
Never disassemble or modify the sensor.

CASCADING

4

٨
٨

٨
٨

٨

٨
٨

٨

٨

Make sure that the power supply is off while adding or removing the amplifiers.
Make sure to check the allowable ambient temperature, as it depends on the 
number of amplifiers connected in cascade.
In case two, or more, amplifiers are connected in cascade, make sure to mount them on a DIN rail.
When the amplifiers move on the DIN rail depending on the attaching condition or
the amplifiers are mounted close to each other in cascade, fit them between the 
optional end plates (

MS-DIN-E

) mounted at the two ends.

When connecting amplifiers not close to each other in parallel, be sure to mount the option-
al end plate (

MS-DIN-E

) at both sides of each amplifier or affix the communication window 

seal of the accessory amplifier protection seal (

FX-MB1

) to the communication window. 

Up to maximum 15 amplifiers can be added (total 16 amplifiers connected in cascade.)
When connecting more than two amplifiers in cascade, use the sub cable (

CN-72-C

غ

)

as the quick-connection cable for the second amplifier onwards.
The settings other than the interference prevention function cannot be transmitted
between this product and other digital fiber amplifiers. Therefore, in case both mod-
els of amplifiers are mounted in cascade, be sure to mount identical models togeth-
er. However, the interference prevention function is not incorporated in the 

FX-301

(

P

)

-HS

 and 

FX-303

(

P

). Take care when the sensors are mounted in cascade.

The communication function of this product and that of the 

FX-301

(

P

)

-F

 is differ-

ent. If these models are mounted in cascade, affix the accessory amplifier protec-
tion seal (

FX-MB1

) to the communication windows of the amplifiers. 

For mounting and removing the amplifier, refer to '

MOUNTING

'.

2

Ԙ

ԙ

Ԛ

ԛ

Mount the amplifiers, one by one, 
on the 35mm width DIN rail.
Slide the amplifiers next to each 
other, and connect the quick-con-
nection cables.
Mount the optional end plates  
(

MS-DIN-E

) at both the ends to hold 

the amplifiers between their flat sides.
Tighten the screws to fix the end 
plates.

Ԙ
ԙ
Ԛ

Loosen the screws of the end plates.
Remove the end plates.
Slide the amplifiers and remove 
them one by one.

Cascading method

Dismantling

I/O CIRCUIT DIAGRAMS

5

٨

NPN output type

D

1

50mA max. (Note 2)

50mA max. (Note 2)

Z

D1

T

r1

T

r2

(Brown) +V (Note 1)

(Black) Output 1

(White) Output 2

+

12 to 24V DC

r

10%

-

(Blue) 0V (Note 1)

1

2

3

4

Color code of quick-connection cable

Terminal No.

Z

D2

Load

Load

Users' circuit

Internal circuit

Sensor circuit

Color code of quick-connection cable

Terminal No.

+

12 to 24V DC

r

10%

-

Load

50mA max. (Note 2)

50mA max. (Note 2)

(Brown) +V (Note 1)

(Black) Output 1

(White) Output 2

(Blue) 0V (Note 1)

D

2

1

2

3

Z

D3

T

r3

T

r4

Z

D4

4

Load

Users' circuit

Internal circuit

Sensor circuit

٨

PNP output type

Notes: 1)

2)

The quick-connection sub cable does not have +V (brown) and 0V 
(blue). The power is supplied from the connector of the main cable.
25mA max. if five, or more, amplifiers are connected in cascade.

Symbols...D

1

, D

2

: Reverse supply polarity protection diode

Z

D1

, Z

D2

, Z

D3

, Z

D4

: Surge absorption zener diode

T

r1

, T

r2

: NPN output transistor

T

r3

, T

r4

: PNP output transistor

Terminal arrangement
diagram

Ԙ

 +V

Ԛ

Output 1

ԛ

Output 2

ԙ

 0V

SPECIFICATIONS

1

MOUNTING

2

Ԙ

ԙ

Fit the rear part of the mounting section of the amplifier 
on a 35mm width DIN rail.
Press down the rear part of the mounting section of the 
unit on the 35mm width DIN rail and fit the front part of 
the mounting section to the DIN rail.

How to mount the amplifier

Ԙ

35mm width DIN rail

ԙ

Ԙ
ԙ

Push the amplifier forward.
Lift up the front part of the amplifier to remove it.

Ԙ

ԙ

Take care that if the front part is lifted without pushing the
amplifier forward, the hook on the rear portion of the mounting section is likely to break.

Note:

How to remove the amplifier

Ԙ
ԙ
Ԛ

Snap the fiber lock lever down.
Insert the fiber cables slowly into the inlets until they stop. (Note 1)
Return the fiber lock lever to the original position, till it stops.

How to connect the fiber cables

Notes: 1)

2)

In case the fiber cables are not inserted to a position where they 
stop, the sensing range reduces. In case of a flexible fiber, take 
care that it may bend inside the amplifier, during insertion.
With the coaxial reflective type fiber, such as, 

FD-G4

 or 

FD-FM2

,

insert the single-core fiber cable into the beam-emitting inlet and 
the multi-core fiber cable into the beam-receiving inlet. If they are 
inserted in reverse, the sensing accuracy will deteriorate.

Ԙ

ԙ

Ԛ

Fiber
lock lever

Fiber

Be sure to fit the attachment to the fibers first before inserting the fibers to the 
amplifier. For details, refer to the instruction manual enclosed with the fibers.

Notes: 1)

2)

3)

4)

50mA per output. 25mA if five, or more, amplifiers are connected in cascade.
When the interference prevention function '      ' is set, the number of mountable fibers 
becomes double. Furthermore, take care that the response time also becomes double.
For the setting method, refer to '

PRO MODE

PRO5 mode setting

'.

When the power supply is switched on, the light emission timing is automatically set for 
interference prevention.
The cable for amplifier connection is not supplied as an accessory. Make sure to use the 
optional quick-connection cables given below.
Main cable (4-core): 

CN-74-C1

(cable length 1m), 

CN-74-C2

(cable length 2m)

CN-74-C5

(cable length 5m)

Sub cable (2-core): 

CN-72-C1

(cable length 1m), 

CN-72-C2

(cable length 2m)

CN-72-C5

(cable length 5m)

13

Teaching (1-level / 2-level / 3-level) / Manual adjustment

Window comparator 
mode

Sensitivity

setting

NPN open-collector transistor

Maximum sink current: each 50mA (Note 1)

Applied voltage: 30V DC or less

(between output and 0V)

Residual voltage: 1.5V or less
[at each 50mA (Note 1) sink current]

PNP open-collector transistor

Maximum source current: each 50mA (Note 1)

Applied voltage: 30V DC or less

(between output and +V)

Residual voltage: 1.5V or less

[at each 50mA (Note 1) source current]

Model No.

12 to 24V DC

r

10% Ripple P-P 10% or less

Supply voltage

Item

FX-305P

FX-305

PNP output

Type

NPN output

Power consumption 
(Note 2)

Normal operation: 960mW or less (current consumption 40mA or less at 24V supply voltage)
ECO mode: 600mW or less (current consumption 25mA or less at 24V supply voltage)

Output
(Output 1, Output 2)

2-level teaching / Limit teaching / Full-auto teaching / Max. sensitivity teaching
/ Manual adjustment

Normal mode

H-SP: 65

Ǵ

s or less, FAST: 150

Ǵ

s or less, STD: 250

Ǵ

s or less

STDF: 700

Ǵ

s or less, LONG: 2.5ms or less, U-LG: 4.5ms or less

selectable with jog switch

Response time

4 digit red LED display

Display

Light-ON or Dark-ON, selectable with jog switch

Output operation

Incorporated

Short-circuit protection

Timer function

Incorporated with variable ON-delay / OFF-delay / ONE-SHOT / ON-
delay

OFF-delay / ON-delay

ONE-SHOT timer, switchable either 

effective or ineffective (Timer: approx. 0.5 to 9999ms)

Incorporated

Fine sensitivity 
adjustment function

Interference prevention
function (Note 2) (Note 3)

Ambient temperature

-10 to +55

͠

 (If 4 to 7 units are connected in cascade: -10 to +50

͠

,

if 8 to 16 units are connected in cascade: -10 to +45

͠

)

(No dew condensation or icing allowed), Storage: -20 to +70

͠

Red LED (modulated)

Emitting element

Enclosure: Heat-resistant ABS, Transparent cover: Polycarbonate
Press switches: Acrylic, Jog switch: Heat-resistant ABS

Material

20g approx.

Weight

35 to 85% RH, Storage: 35 to 85% RH

Ambient humidity

Incorporated [up to four fibers can be mounted adjacently (However,
U-LG mode is eight fibers, H-SP mode is two fibers.)]

Accessory

FX-MB1

(Amplifier protection seal): 1 set

Main cable (

CN-74-C

غ

)

(optional)

End plates (

MS-DIN-E

)

(optional)

End plates (

MS-DIN-E

)

(optional)

Sub cable (

CN-72-C

غ

)

(optional)

Slide

Slide

Thank you very much for purchasing Panasonic products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.

INSTRUCTION MANUAL

Digital Fiber Sensor Amplifier

FX-305

(

P

)

MJE-FX305 No.0034-49V

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Содержание FX-305

Страница 1: ...r circuit ٨ PNP output type Notes 1 2 The quick connection sub cable does not have V brown and 0V blue The power is supplied from the connector of the main cable 25mA max if five or more amplifiers are connected in cascade Symbols D1 D2 Reverse supply polarity protection diode ZD1 ZD2 ZD3 ZD4 Surge absorption zener diode Tr1 Tr2 NPN output transistor Tr3 Tr4 PNP output transistor Terminal arrangem...

Страница 2: ...switch in the object absent condition If the teaching is accepted the read incident light intensity blinks in the digital display Ԛ Turn Jog switch to the side or the side If Jog switch is turned to side the threshold value level is shifted to a value approx 15 higher lower sensitivity than that set at Ԙ If Jog switch is turned to side the threshold value level is shifted to a value approx 15 lowe...

Страница 3: ...E SHOT timer Note 2 Press Press Press Press Turn Turn Turn The range of available timer delays is 0 5ms 1 to 9999ms 1ms increments Turn Press Turn The range of available timer delays is 0 5ms 1 to 500ms 1ms increments Turn Notes 2 For OFF delay ON delay or ON delay ONE SHOT timer follow the procedure giv en below for setting Press Press Press Press Without timer Without timer Notes 1 For the incid...

Страница 4: ...d is displayed The factory setting is When the code setting function is used refer to the Code setting table given below However the code setting is only for the output 1 PRO6 mode setting Normal mode Window comparator mode Press Press Press Press Press Press Press Press Press Rising differential mode Trailing differential mode Turn Turn Turn Turn Turn Press Press Press Press Turn Press Normal mod...

Отзывы: