3-6
Example 2) When specifying TS for [S1] and [S2], and LD for [D]
(transferring only lower one word)
S1: TS5, S2: TS7, D: LD20
TS4
11112222h
LD20
4444h
TS5
00004444h
LD21
6666h
TS6
55556666h
LD22
8888h
TS7
77778888h
LD23
1234h
TS8
9999AAAAh
LD24
5678h
Precautions during programming
In the case of a direct address and index modification address, specify the same type of
device for [S1] and [S2]. Besides, specify [S2] to be equal to or larger than [S1].
Flag operation
Name
Description
Latest error
(SR7)
Hold error
(SR8)
To be set in case of out-of-range values in indirect access (index modification, pointer access).
To be set when S1 is larger than S2.
To be set when the destination range is out of the accessible range.