Parts and Its Functions
FP2 Multi-wire Link Unit
2 - 8
2.2
Switch Settings
2.2.2
Mode Selector Switches (1)
Operation mode
Terminal station: With MEWNET, the units at both ends of the network must be
specified as “terminal stations”.
(Front)
When the unit is shipped from the factory, all switches are set to the “OFF” position.
No Item
Setting contents
No. Item
W mode
W2 mode
F mode
1
Operation
OFF
PC link mode
Operation stops if a
communication error occurs.
1
Operation
mode
ON
Not PC link mode
Operation continues if a
communication error occurs.
2
3
4
Not used
—
—
—
5
6
7
Terminal
Set to terminal
station
ON
OFF
8
Terminal
station
Not set to terminal
station
ON
OFF
.
Notes
D
The settings of the mode selector switches (1) and (2) should
always be changed with the power off. The setting will be ef-
fective the next time that the power is turned on. (If the setting
is changed with the power on, be aware that the setting in ef-
fect when the power was turned on will remain effective.)
D
Only the settings of the mode selector switches (1) No. 7 and
No. 8 (terminal station settings) will be effective at the instant
that they are changed.
Содержание FP2 Series
Страница 1: ...PROGRAMMABLE CONTROLLER FP2 Multi wire Link Unit Technical Manual ARCT1F302E 2 2008 11...
Страница 3: ......
Страница 8: ......
Страница 10: ...General Specifications FP2 Multi wire Link Unit 1 2...
Страница 26: ...General Specifications FP2 Multi wire Link Unit 1 18 1 4 Confirming the Design Contents...
Страница 28: ...Parts and Its Functions FP2 Multi wire Link Unit 2 2...
Страница 36: ...Parts and Its Functions FP2 Multi wire Link Unit 2 10 2 2 Switch Settings...
Страница 37: ...Chapter 3 Wiring 3 1 Wiring 3 3 3 1 1 Transmission Cable Wiring 3 3 3 1 2 Crimp Terminal Specifications 3 4...
Страница 38: ...Wiring FP2 Multi wire Link Unit 3 2...
Страница 42: ...MEWNET W Mode FP2 Multi wire Link Unit 4 2...
Страница 52: ...MEWNET W Mode FP2 Multi wire Link Unit 4 12 4 2 PC Link...
Страница 54: ...What to Check If a Problem Occurs FP2 Multi wire Link Unit A 2...
Страница 60: ...What to Check If a Problem Occurs FP2 Multi wire Link Unit A 8 A 4 What to Do If a Transmission Error Occurs...
Страница 61: ...Appendix B Dimensions...
Страница 62: ...Dimensions FP2 Multi wire Link Unit B 2...
Страница 63: ...Dimensions FP2 Multi wire Link Unit B 3 unit mm in 28 1 102 100 3 937 12 6 0 496 93 3 661...
Страница 64: ...Dimensions FP2 Multi wire Link Unit B 4...
Страница 67: ......
Страница 68: ...ARCT1F302E 2 200811 ACG M302E 2...