General Specifications
FP2 Multi-wire Link Unit
1 - 16
1.4
Confirming the Design Contents
1.4
Confirming the Design Contents
1.4.1
Confirming the Current Consumption
When the system architecture is configured, the internal current consumption of the Mul-
ti - wire link unit (with a 5 V DC power supply) should be kept within the range of the power
supply unit, taking into consideration the conditions under which other units are used.
Product name
Order number
Current consumption (at 5 V DC)
FP2 Multi - wire link unit
FP2 - MW
220mA or less
For information on the internal current consumption of other units, refer to the FP2 Hard-
ware Manual and the manuals for the other units.
1.4.2
Confirming I/O Allocations
When a FP2 Multi - wire link unit is installed, it automatically occupies 16SE (16 points).
This can be changed to 0SE, however, using the NPST - GR programming software.
Содержание FP2 Series
Страница 1: ...PROGRAMMABLE CONTROLLER FP2 Multi wire Link Unit Technical Manual ARCT1F302E 2 2008 11...
Страница 3: ......
Страница 8: ......
Страница 10: ...General Specifications FP2 Multi wire Link Unit 1 2...
Страница 26: ...General Specifications FP2 Multi wire Link Unit 1 18 1 4 Confirming the Design Contents...
Страница 28: ...Parts and Its Functions FP2 Multi wire Link Unit 2 2...
Страница 36: ...Parts and Its Functions FP2 Multi wire Link Unit 2 10 2 2 Switch Settings...
Страница 37: ...Chapter 3 Wiring 3 1 Wiring 3 3 3 1 1 Transmission Cable Wiring 3 3 3 1 2 Crimp Terminal Specifications 3 4...
Страница 38: ...Wiring FP2 Multi wire Link Unit 3 2...
Страница 42: ...MEWNET W Mode FP2 Multi wire Link Unit 4 2...
Страница 52: ...MEWNET W Mode FP2 Multi wire Link Unit 4 12 4 2 PC Link...
Страница 54: ...What to Check If a Problem Occurs FP2 Multi wire Link Unit A 2...
Страница 60: ...What to Check If a Problem Occurs FP2 Multi wire Link Unit A 8 A 4 What to Do If a Transmission Error Occurs...
Страница 61: ...Appendix B Dimensions...
Страница 62: ...Dimensions FP2 Multi wire Link Unit B 2...
Страница 63: ...Dimensions FP2 Multi wire Link Unit B 3 unit mm in 28 1 102 100 3 937 12 6 0 496 93 3 661...
Страница 64: ...Dimensions FP2 Multi wire Link Unit B 4...
Страница 67: ......
Страница 68: ...ARCT1F302E 2 200811 ACG M302E 2...