FP0 – Impressive Capabilities

High specifications for both speed and capacity

0.9µs per basic instruction. Pulse catch and interrupt input functions meet the need for high-speed response.

High-speed execution

Execution speed of 0.9µs per basic instruction. 500 steps program yields a scanning time of 1ms, which means the FP0
boosts the fastest processing time among the products of this class.
• Internal processing in the FP0

Large capacity

Pulse catch function

Can read pulses as short as 50µs, which greatly facilitates
sensor input.
• Pulse catch function

Interrupt input function

Accurate processing, unaffected by scan time
• Interrupt input function

I/O

refresh

Program

execution

I/O

refresh

Program

execution

1 scan

I/O

refresh

Program

execution

Internal processing in the FP0

I/O

refresh

Program

execution

I/O

refresh

Program

execution

Sensor input

signal

Cannot
read.

Lengthening

of sensor

input signal

Can
read!

With pulse catch function

Internal processing in the FP0

I/O

refresh

Program

execution

I/O

refresh

Program

execution

Interrupt
program

Interrupt input

Interrupt program executed when
interrupt input enters. 

A top-class large 5k and 10k steps program capacity housed within a compact body. Furthermore, data capacity for internal
devices like the data register is also ample. The unit's high performance is even suited to complicated controls 
and controls with multiple amounts of data.

I/O 10-point, 14-point, 16-point type

Control unit type

I/O 32-point type

2 720 steps

1 660 words

5 000 steps

6 144 words

1 008 points

144 points

   

FP0-T32 CP/T

10 000 steps

16 383 words

Program size

Internal relays

Timers/Counters

Data registers

FP0_broschüre_4093 euen0904  15.10.2004  8:42 Uhr  Seite 6

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: [email protected]

Содержание FP0 Series

Страница 1: ...FP0 Series Programmable Controller Panasonic the new name for CTi Automation Phone 800 894 0412 Fax 208 368 0415 Web www ctiautomation net Email info ctiautomation net...

Страница 2: ...d to I O 32 points control unit Choose among 3 types of attachment DIN rail Slim attachment plate model Flat attachment plate model cannot be used with expansions Input output terminal TOOL Port Hooks...

Страница 3: ...ontrol Parts feeders Food processing and packaging machines Parking meters Auto stockers Driving range Easy Expansion up to 128 I Os Control unit Expansion unit Expansion unit Expansion unit Maximum p...

Страница 4: ...his event the maximum number of I O points when using a relay output type control panel is 110 10 points Input 6 points FP0 C10RSA FP0 C10CRSA with 2nd RS232C FP0 C14CRSA with 2nd RS232C FP0 C16PA PNP...

Страница 5: ...put type Analogue I O Units Thermocouple and RTD Units Networking Units PROFIBUS FP0 DPS2 DP Slave MEWNET F FP0 IOL MEWNET F Slave S Link CPU FP0 SL1 S LINK Master FP0 E16RSA FP0 E8XA FP0 E16XA FP0 E8...

Страница 6: ...0 I O refresh Program execution I O refresh Program execution Sensor input signal Cannot read Lengthening of sensor input signal Can read With pulse catch function Internal processing in the FP0 I O r...

Страница 7: ...ade control signal Encoder output inputted into high speed counter Serial communication function The FP0 s second RS232C port types C10CRS C14CRS C16C C32C and T32C allows direct connection to compute...

Страница 8: ...FP0 C14CRS FP0 C16C FP0 C32C and FP0 T32C offers flexible programming i e General Purpose In this configuration it is possible to realise communication connections with different RS232C peripheral dev...

Страница 9: ...t body Input output status can be verified at a glance Terminal type can be plugged straight in without resorting to crimping made by Phoenix Contact Co Can handle wires from 0 3 to 1 25mm2 Compatible...

Страница 10: ...3 75 187 5 500 1 500 3 000 6 000 12 000 Kbaud automatic baud rate detection Range of adresses that can be set 0 125 PROFIBUS connection Configuration 9 pin D sub connector 2 words input 2 words output...

Страница 11: ...time filtering Clock Calendar function Available Available Not available None Other Built in Functions Item Description Number of I O points Expansion S LINK block 64 input points 64 output points fi...

Страница 12: ...Number of control I O points per an I O link unit 64 points Input 32 points and Output 32 points Remote I O map allocation Interface Transmission error check 32X 32Y Conforms to RS485 CRC Cyclic Redu...

Страница 13: ...sion temperature control at low cost 13 Temperature control FP0 TC8 8 channels FP0 TC4 4 channels Item Specification Input points Input range Up to 8 channels per unit The number of input points can b...

Страница 14: ...s to factory production systems Each CPU supports up to 3 FP0 analogue units Combination with digital and analogue expansion units is freely allowed Highest performance is offered with 12 bit resoluti...

Страница 15: ...minal temperature selectable J up to 750 C or 100 C to terminal temperature selectable T up to 350 C or 100 C to terminal temperature selectable 0 to 5V 0 to 20mA K 0 to K 4000 H 0000 to H 0FA0 1 10 t...

Страница 16: ...ntrolled electrical installations The library includes linear and non linear controller types such as the P I PI PID controller and two points three points controller with and without hysteresis Progr...

Страница 17: ...relay MCR 32 points Number of labels JMP and LOOP 64 labels 255 labels Differential points Unlimited number of points Number of step ladder 128 stages 704 stages Number of subroutines 16 subroutines...

Страница 18: ...input voltage 24VDC Operating voltage range 21 6 to 26 4VDC Rated input current 4 3mA or less at 24VDC Input points per common 6 points common C10RS 8 points common C14RS C16T C16P E16T E16P 16 points...

Страница 19: ...b Fewer errors through defined data types and encapsulation Well structured through programme organisation units task and project management Online monitoring and diagnostic Ethernet and Modem communi...

Страница 20: ...n on site a mouse is not required for input search write monitor and timer edit operations Everything can be accomplished with a keyboard alone 2 Standard Windows operations such as copy and paste are...

Страница 21: ...off status and register values and perform calculations based on register values Excel macros are not necessary PCWAY The connection between PLC and SCADA software Provides a standard interface betwee...

Страница 22: ...number FP0 C32PA PNP FP0 C32TA NPN PNP NPN output type Order number FP0 C32CPA PNP FP0 T32CPA PNP 10K FP0 C32CTA NPN FP0 T32CTA NPN 10K with 2nd RS232C interface Terminal type Order number FP0 C14RSA...

Страница 23: ...24VDC 2 1A PROFIBUS PROFIBUS DP Slave or Remote I O Order number FP0 DPS2 MEWNET F MEWNET F Slave Order number FP0 IOL S LINK CPU S LINK Master Order number FP0 SL1 Order number AFP1114V2 Networking...

Страница 24: ...uter With 30cm dedicated cable Power source unnecessary Order number AFP15402 DIN rail Standard DIN rail of width 35mm 1 378inch and length 1m Order number Stopper fitting DIN rail stopper fitting ATA...

Страница 25: ...are USB port dongle Control CommX Order number AFW20011 Software Printer port dongle AFW20031 Software USB port dongle MEWTOCOL OPC Server Order number AFPS01510 1 license AFPS01515 5 licenses AFPS015...

Страница 26: ...Shock resistance Life time min Mounting Size Input connection AC side Output connection DC side Status display 0 C to 55 C 20 C to 70 C 5 to 95 non condensing 5 to 95 non condensing 10 to 55Hz 1 cycl...

Страница 27: ...tput FP0 A21A FP0 A80 8 analogue inputs FP0 A80A FP0 TC4 4 thermocouple inputs FP0 TC4 FP0 TC8 8 thermocouple inputs FP0 TC8 FP0 RTD6 6 RTD Inputs Pt 100 Pt 1000 Ni 1000 FP0 RTD6 3 AC Power Supply Pro...

Отзывы: