Programming Tools and Current Consumption List
Products and order numbers
25
Control
Control
Made in Germany
Made in Germany
Matsushita Electric Works, Ltd.
1995-2000
1995-2000
Matsushita Electric Works, Ltd.
FPWIN GR
FPWIN GR
Ver.2
Ver.2
Control
Control
Made in Germany
Made in Germany
Matsushita Electric Works(Europe)AG
1995-2000
1995-2000
Matsushita Electric Works(Europe)AG
FPWIN Pro
FPWIN Pro
Ver.5
Ver.5
Control FPWIN Pro
English, German, French, Italian,
Spanish, Japanese menu selectable.
According to IEC 61131-3 Standard
Order number:
■
small version for MINI-PLC only
(FP0, FP-e, FPM, FP1, FP
∑
(Sigma)
• FPWINPROSEN (English manual)
• FPWINPROSDE (German manual)
• FPWINPROSFR (French manual)
■
full version for all FP-Series PLCs
• FPWINPROFEN (English manual)
• FPWINPROFDE (German manual)
• FPWINPROFFR (French manual)
Programming software and cables
Other Software Tools
Current consumption list
Control FPWIN GR
English, Italian, Spanish,
menu selectable
Order number:
■
full version for all FP-Series PLCs:
• FPWINGR F2 (English manual)
Programming cable
PC (D-SUB 9-pin) to the PLC
(mini-DIN 5-pin)
Order number:
AFC8513
Programming cable
for use with FP Programmers
D-SUB15-pin, mini-DIN 5-pin
Order number:
AFC8523
PCWAY
Order number:
AFW10011 (Software
+ Printer port dongle)
AFW10031 (Software
+ USB port dongle)
Control CommX
Order number:
AFW20011 (Software
+ Printer port dongle)
AFW20031 (Software
+ USB port dongle)
MEWTOCOL
OPC Server
Order number:
AFPS01510 (1 license)
AFPS01515 (5 licenses)
AFPS01516 (10 licenses)
Type of unit
Part number
Current Consumption
Supply to the power supply connector of the control unit *1
Supply to the power supply connector of the expansion and intelligent units *2
Control unit
C10 series, C14 series
100mA or less
—
C16 series
40mA or less
—
C32 series, T32 series
60mA or less
—
SL1
150mA or less
—
Expansion unit
E8X
10mA or less
—
E8YRS
10mA or less
100mA or less
E8YT, E8YP
15mA or less
—
E8R
20mA or less
50mA or less
E16R
20mA or less
100mA or less
E16X
20mA or less
—
E16T, E16P, E16YT, E16YP
25mA or less
—
E32T, E32P
40mA or less
—
Intelligent unit
A21
20mA or less
100mA or less
A80
20mA or less
60mA or less
PROFIBUS unit
FP0-DPS2
10mA or less
100mA or less
FP programmer
AFP1114V2
50mA or less
—
C-NET adapter
AFP15402
50mA or less
—
IOL
30mA or less
40mA or less
TC4,TC8, RTD6
25mA
—
Notes)
*1 The current consumption from the power supply connector block of the control unit. Calculate the total current consumption based on the combination of the units.
*2 The current consumption from the power supply connector block of the expansion unit and intelligent unit.
A04V
20mA or less
100mA or less
A04I
20mA or less
130mA or less
FP0_broschüre_4093 euen0904 15.10.2004 8:44 Uhr Seite 25
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: [email protected]