Panasonic FP-X Скачать руководство пользователя страница 9

"Require slightly more functions", "Want to add functions to the existing equipment" 

- The rich variety of add-on cassettes helps solve these requirements.

8

9

Add-on Cassette (Lineup)

 The 

Add-on cassette 

easily adds small quantities of functions and I/O points.

This Ethernet cassette meets user needs such as the "easy collection of inspection/

production data using LAN (Ethernet)" or "remote changing of ladder programs".

Add-on Cassette (Ethernet)

 The industry's first*

1

 add-on to equip a compact PLC with an Ethernet port

Easily removable 
(Two screws to secure the unit)

Attachment position (see the table above)

Max. number of attachable cassettes

C14

A, upper

A, lower

C14

2 cassettes

C30, C60

3 cassettes

C30

C60

B

(Not attachable)

Add-on Cassette

Communication Cassette 

(Only one of these cassettes 
can be attached.)

Part number

Specifications

Attachable position (see the figure below)

A, lower A, upper

B

C

Application Cassette

Only a backup battery can be attached.

I/O cassette

Input cassette

Output cassette

Pulse I/O cassette 

Analog input cassette

Analog output cassette

Analog I/O cassette

Thermocouple input 
cassette

Master memory cassette 

(Only one cassette can be attached.)

AFPX-IN4T3

AFPX-IN8

AFPX-TR8

AFPX-TR6P

AFPX-PLS

AFPX-AD2

AFPX-DA2

AFPX-A21

AFPX-TC2

AFPX-MRTC

AFPX-COM1

AFPX-COM2

AFPX-COM3

AFPX-COM4

AFPX-COM5

AFPX-COM6

8-point input of 24 V DC, Bi-direction (Sink/Source)

8-point output of 24 V DC, NPN transistor 0.3 A

6-point output of 24 V DC, PNP transistor 0.5 A

A: Available, N/A: Not available

4-point input of 24 V DC, Bi-direction (Sink/Source)

3-point output of 24 V DC, NPN transistor 0.3 A

High-speed counter input: single phase 80 kHz 2 ch. or 2-phase 30 kHz 1 ch.

Pulse output: 1 axis 100 kHz (CW/CCW, Pulse + Sign)

2-point analog input, 0 to 10 V or 0 to 20 mA, 12-bit, 2 ms/2 ch.

2-point analog output, 0 to 10 V or 0 to 20 mA, 12-bit, 2 ms/2 ch.

2-point analog input, 0 to 5 V, 0 to 10 V or 0 to 20 mA, 12-bit, 2 ms/2 ch.

1-point analog output, 0 to 10 V or 0 to 20 mA, 12-bit, 1 ms/1 ch.

2-point thermocouple input, K/J type, Resolution: 0.2

°

C, 200 ms/2 ch., Channels insulated

32 k steps program All comment saving/transfer, Calendar timer (Real-time clock)

RS232C 1 ch.

RS232C 2 ch.

RS485/RS422 selectable 1 ch. 

RS485 1 ch. + RS232C 1 ch.

Ethernet 1 ch + RS232C 1 ch.

RS485 2 ch.

(Cannot be used with a transistor 
output type control unit.)

 Enables easy Ethernet connections with a compact PLC, which have been previously abandoned.

 Also equipped with an RS232C port. Together with the tool port (programming port), a total of three 

communication ports are available, which is remarkable for a compact PLC.

 For example, the following operations are simultaneously available with this cassette attached:

1. I/O control

2. Reading data from a tester (measuring instrument) of inspection equipment (RS232C)

3. Collecting the read data from the host computer (Ethernet)

4. Setting/monitoring by a touch panel (Tool port)

 AFPX-COM5

RS232C

Ethernet

*1: In Japan, as of May 1, 2007

 Application

 Specifications

Tool port

Tool port

Tool port

Ethernet

Ethernet

Internet connection

Program editing/monitoring

Ethernet

RS232C

Measuring 
instrument

Measuring 
instrument

Measuring 
instrument

Touch 
panel

Touch 
panel

Touch 
panel

Operation data managing software
PCWAY

Programming software
FPWIN GR
FPWIN Pro

RS232C

RS232C

Data collection

Remote maintenance

10BASE-T, 100BASE-TX, TCP/IP, Baud rate: 9600 bps/115200 bps

• Computer link (3 connections max.)

• General-purpose serial communications (1 connection max.) 
  

 Server function, client function

3-wire (RD, SD, SG), Asynchronous, Baud rate: 300 bps to 115200 bps

• Computer link

• General-purpose serial communications

• Modbus-RTU master/slave

• Automatically sends responses without communication programs 

  to commands of Matsushita's open protocol "MEWTOCOL".

• Contact/word data writing/reading, program editing

• PCWAY, FPWIN GR and FPWIN Pro are supported.

• Waits for a connection from a client PC (personal computer), and 

  after the connection is established, receives data from the PC.

• After the power is turned on, establishes a connection to a 

  preset IP address and sends data.

Ethernet
(COM1)

RS232C
(COM2)

Interface

Specifications and functions

Computer link

General-
purpose 
serial 
communi-
cations

Ethernet port functions

Specifications

Server 
function

Client 
function

Use our free software "Configurator WD" for setting up 
the Ethernet port (e.g. IP address and operation mode).

Download the software free of charge from: 

http://www.mew.co.jp/ac/e

A, upper

A, lower

A, upper

A, lower

B

C

• Only section A has an upper side 

available to attach the cassette.

• No add-on cassettes can be 

attached to section C. Only a 
backup battery can be attached.

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

N/A

N/A

N/A

N/A

N/A

N/A

NEW

NEW

NEW

NEW

NEW

NEW

Содержание FP-X

Страница 1: ...RUN ERR FP X C14 7 4 0 0 3 4 Y X 3 V1 RUN PROG V0 5 X6 X4 X3 L N X7 X0 X2 COM X5 X1 Y1 Y0 0V 24V Y5 C0 C1 C2 C3 Y4 Y3 Y2 Panasonic ERROR I F POWER AFPX EFP0 AFPX C60 7 0 5 3 5 90 60 25 90 60 90 100 9...

Страница 2: ...re controllers and power meters General purpose Serial Communications Commands are generated transmitted in accordance with the communication protocol of the target equipment Or nonprocedural data rec...

Страница 3: ...re controllers and power meters General purpose Serial Communications Commands are generated transmitted in accordance with the communication protocol of the target equipment Or nonprocedural data rec...

Страница 4: ...t of 24 V DC 6 point output of 2 A relay 16 point input of 24 V DC 14 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A...

Страница 5: ...t of 24 V DC 6 point output of 2 A relay 16 point input of 24 V DC 14 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A...

Страница 6: ...ords 14 words 256 points 256 labels Up to program capacity 1000 stages 500 subroutines Relay output type 15 programs 14 external 1 constant Transistor output type 9 programs 8 external 1 constant 0 5...

Страница 7: ...ords 14 words 256 points 256 labels Up to program capacity 1000 stages 500 subroutines Relay output type 15 programs 14 external 1 constant Transistor output type 9 programs 8 external 1 constant 0 5...

Страница 8: ...with a transistor output type control unit Enables easy Ethernet connections with a compact PLC which have been previously abandoned Also equipped with an RS232C port Together with the tool port prog...

Страница 9: ...with a transistor output type control unit Enables easy Ethernet connections with a compact PLC which have been previously abandoned Also equipped with an RS232C port Together with the tool port prog...

Страница 10: ...perfectly fits the need for low cost multi axis positioning control in small scale equipment Built in 4 axis Pulse Output Transistor Output Type The transistor output type C14 comes with 3 axis while...

Страница 11: ...perfectly fits the need for low cost multi axis positioning control in small scale equipment Built in 4 axis Pulse Output Transistor Output Type The transistor output type C14 comes with 3 axis while...

Страница 12: ...e FP X as a slave automatically sends responses to MEWTOCOL commands sent from a master station such as a personal computer up to 3 communication ports Computer link MEWTOCOL slave General purpose ser...

Страница 13: ...e FP X as a slave automatically sends responses to MEWTOCOL commands sent from a master station such as a personal computer up to 3 communication ports Computer link MEWTOCOL slave General purpose ser...

Страница 14: ...ided for data and real time clock One battery for C14 two for C30 and three for C60 can be attached A two battery installation can operate for a long time 10 years or more without maintenance Real tim...

Страница 15: ...ided for data and real time clock One battery for C14 two for C30 and three for C60 can be attached A two battery installation can operate for a long time 10 years or more without maintenance Real tim...

Страница 16: ...64 MB depends on OS At least 1024 768 High Color 16 bit or higher FP X FP e FP0 FP FP1 FP M FP2 FP2SH FP3 FP10SH Relay output type Ver 5 1 and after Transistor output type Ver 5 3 and after 17 16 Pro...

Страница 17: ...64 MB depends on OS At least 1024 768 High Color 16 bit or higher FP X FP e FP0 FP FP1 FP M FP2 FP2SH FP3 FP10SH Relay output type Ver 5 1 and after Transistor output type Ver 5 3 and after 17 16 Pro...

Страница 18: ...ond day of week optional battery required RS232C 1 ch RS and CS control signal equipped non insulated RS232C 2 ch non insulated RS485 RS422 selectable 1ch insulated RS485 1 ch insulated RS232C 1 ch no...

Страница 19: ...ond day of week optional battery required RS232C 1 ch RS and CS control signal equipped non insulated RS232C 2 ch non insulated RS485 RS422 selectable 1ch insulated RS485 1 ch insulated RS232C 1 ch no...

Страница 20: ...d terminal cable 5 A PNP 0 1 A 24 V DC transistor output type is also available When ordering it please replace T in the end of product number for the NPN type with P Control FPWIN Pro IEC61131 3 comp...

Страница 21: ...d terminal cable 5 A PNP 0 1 A 24 V DC transistor output type is also available When ordering it please replace T in the end of product number for the NPN type with P Control FPWIN Pro IEC61131 3 comp...

Страница 22: ...n Over voltage category 100 to 240 V AC AC power 24 V DC DC power 85 to 264 V AC AC power 20 4 to 28 8 V DC DC power C14 24V DC 0 15A C30 and C60 24V DC 0 4A 10 ms or more 0 to 55 C 40 to 70 C 10 to 9...

Страница 23: ...n Over voltage category 100 to 240 V AC AC power 24 V DC DC power 85 to 264 V AC AC power 20 4 to 28 8 V DC DC power C14 24V DC 0 15A C30 and C60 24V DC 0 4A 10 ms or more 0 to 55 C 40 to 70 C 10 to 9...

Страница 24: ...RUN ERR FP X C14 7 4 0 0 3 4 Y X 3 V1 RUN PROG V0 5 X6 X4 X3 L N X7 X0 X2 COM X5 X1 Y1 Y0 0V 24V Y5 C0 C1 C2 C3 Y4 Y3 Y2 Panasonic ERROR I F POWER AFPX EFP0 AFPX C60 7 0 5 3 5 90 60 25 90 60 90 100 9...

Отзывы: