Panasonic FP-X Скачать руководство пользователя страница 21

20

21

Product name

Part number

Description

Programmable Display GT Series

GT01 Main Unit

GT01R Main Unit

GT11 Main Unit

GT21C Main Unit

GT32M Main Unit

GT32T0 Main Unit

GT32T1 Main Unit 

RS232C type

RS422/RS485 type

RS232C type

RS422/RS485 type

RS232C type

RS422/RS485 type

RS232C type

RS422/RS485 type

RS232C type

RS422/RS485 type

RS232C type

RS422/RS485 type

RS232C type

RS422/RS485 type

RS232C type

RS422/RS485 type

RS232C type

RS422/RS485 type

5V DC

24V DC

5V DC

24V DC

24V DC

24V DC

24V DC

24V DC

24V DC

Black

Ash gray

Black

Ash gray

Black

Ash gray

Black

Ash gray

Pure black

Silver

Pure black

Silver

Pure black

Silver

Pure black

Silver

Black

Ash gray

Black

Ash gray

Black

Silver

Black

Silver

Pure black

Silver

Pure black

Silver

Pure black

Silver

Pure black

Silver

Pure black

Silver

Pure black

Silver

STN monochrome LCD

STN monochrome LCD

STN monochrome LCD

STN color LCD

TFT monochrome LCD

TFT color LCD

TFT color LCD

AIGT0030B1

AIGT0030H1

AIGT0032B1

AIGT0032H1

AIGT0030B

AIGT0030H

AIGT0032B

AIGT0032H

AIGT0230B1

AIGT0230H1

AIGT0232B1

AIGT0232H1

AIGT0230B

AIGT0230H

AIGT0232B

AIGT0232H

AIGT2030B

AIGT2030H

AIGT2032B

AIGT2032H

AIGT2230B

AIGT2230H

AIGT2232B

AIGT2232H

AIG32MQ02D

AIG32MQ03D

AIG32MQ04D

AIG32MQ05D

AIG32TQ02D

AIG32TQ03D

AIG32TQ04D

AIG32TQ05D

AIG32TQ12D

AIG32TQ13D

AIG32TQ14D

AIG32TQ15D

(Ethernet and sound 
output function supported)

Related Products

Related Products List

Related Products

Related Products List

FP0 Expansion Units

Product name

FP0 E8 Expansion Unit

FP0 E16 Expansion Unit

FP0 E32 Expansion Unit

Number of I/O points

Power supply 

voltage

Input

Output

Connection type

Part number

Product number

Specifications

AFP03003

AFP03023

AFP03013

AFP03020

AFP03040

AFP03303

AFP03323

AFP03313

AFP03343

AFP03340

AFP03543

FP0-E8X 

FP0-E8RS 

FP0-E8RM 

FP0-E8YRS 

FP0-E8YT 

FP0-E16X 

FP0-E16RS 

FP0-E16RM 

FP0-E16T 

FP0-E16YT 

FP0-E32T

8

8

8

8

16

16

16

16

32

Input: 8

Input: 4
Output: 4

Output: 8

Output: 8

Input: 16

Input: 8
Output: 8

Input: 8
Output: 8

Output: 16

Input: 16
Output: 16

24 V DC

24 V DC

24 V DC

24 V DC Sink/Source (

±

common)

24 V DC Sink/Source (

±

common)

24 V DC Sink/Source (

±

common)

24 V DC Sink/Source (

±

common)

24 V DC Sink/Source (

±

common)

24 V DC Sink/Source (

±

common)

Relay output: 2 A

Relay output: 2 A

Transistor output: 

NPN 0.1 A/5 to 24 V

Relay output: 2 A

Transistor output: 

NPN 0.1 A/5 to 24 V

Transistor output: 

NPN 0.1 A/5 to 24 V

Transistor output: 

NPN 0.1 A/5 to 24 V

MIL connector

Terminal block

Molex connecter

Terminal block

MIL connector

MIL connector

Terminal block

Molex connecter

MIL connector

MIL connector

MIL connector

Notes: 1) The relay output type expansion units come with a power cable (part number AFP0581). (The transistor output type needs no power cable.)

2) The terminal block type relay output units have 2 terminal blocks (9 pins) made by Phoenix. Use a 2.5 mm wide screwdriver. 

Preferably use the specific terminal block screwdriver (part number AFP0806, Phoenix type code SZS 0. 4 

×

 2.5 mm) or equivalent.  

3) The connector-type relay output units have 2 connectors made by Nihon Molex (Molex type code 51067-0900, 9 pins). 

Use the specific Molex connector press-fit tool (part number AFP0805, Nihon Molex type code 57189-5000) or equivalent.

4) The transistor output units have a press-fit socket for wire-pressed terminal cable and contacts. Use the press-fit tool (part number AXY52000) for wire-pressed terminal cable.
5) A PNP 0.1 A/24 V DC transistor output type is also available. When ordering it, please replace "T" in the end of product number for the NPN type with "P".

Control FPWIN Pro 

(IEC61131-3 compliant Windows version software)

Control FPWIN GR for Windows

*The production of FP1, FP-M, FP3/FP10SH has been discontinued.
Note) FP-X compatible versions: Relay output type - Ver. 2.50 or later; Transistor output type - Ver. 2.70 or later

*The production of FP1, FP-M, FP3/FP10SH has been discontinued.
Note) FP-X compatible versions: Relay output type - Ver. 5.1 or later; Transistor output type - Ver. 5.3 or later

FP0 Intelligent Units

FP0 Link Units

Product name

Specifications

Part number

Product number

AFP0420

AFP0421

AFP0480

AFP0401

AFP04121

AFP04123

FP0-TC4

FP0-TC8

FP0-A21

FP0-A80

FP0-A04V

FP0-A04I

FP0 Thermocouple unit

FP0 Analog I/O unit

FP0 A/D Converter Unit

FP0 D/A Converter Unit

K, J, T, R

 thermocouple, Resolution: 0.1 

°

C

K, J, T, R thermocouple, Resolution: 0.1 

°

C

<Input specifications>

Number of channels:

2 channels

Input range:

0 to 5 V, –10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)

<Output specifications>

Number of channels:

1 channel

Output range:

–10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000) 

<Input specifications>

Number of channels:

8 channels

Input range:

0 to 5, –10 to +10 V, –100 to 100 mV (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000) 

<Output specifications>

Number of channels:

4 channels

Output range:

–10 to +10 V (Resolution: 1/4000)
4 to 20 mA (Resolution: 1/4000) 

Power supply 

voltage

Product name

Specifications

Part number

Product number

FP0 CC-Link Slave unit

FP0 I/O Link unit

AFP07943

AFP0732

FP0-CCLS

FP0-IOL

24 V DC

24 V DC

This unit is for making the FP0 function as a slave station of the CC-Link. 
Only one unit can be connected to the furthest right edge of the FP0 expansion bus.

Note: Accuracy will change if an FP0 thermocouple unit is used at the same time. For details, please refer to the FP0 catalog 

or to the CC-Link Unit manual.

This is a link unit designed to make the FP0 function as a station to MEWNET-F (remote I/O system).

FP

Σ

FP0

.

FP-e

FP3*

.

FP10SH

FP0

10k

FP1*

FP2

FP2SH FP-M*

FP-X

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

N/A

N/A

N/A

A

FPWIN GR
for Windows 

Product name

Type

Part number

English: Full type

English: Small type

English: Ver. up type

Chinese

Chinese: Ver. up type

Korean

CD-ROM for Windows

CD-ROM for Windows

CD-ROM for Windows

CD-ROM for Windows

CD-ROM for Windows

CD-ROM for Windows

AFPS10520

AFPS11520

AFPS10520R

AFPS10820

AFPS10820R

AFPS10920

Applicable PLC

A: Available, N/A: Not available

A

A

A

A

A

A

A

A

A

A

A

N/A

A

A

A

N/A

A

N/A

FP

Σ

FP0

.

FP-e

FP3*

.

FP10SH

FP0

10k

FP1*

FP2

FP2SH FP-M*

FP-X

FPWIN Pro
for Windows 

Product name

Type

Part number

English: Full type

English: Small type

AFPS50550

AFPS51550

CD-ROM for Windows

CD-ROM for Windows

Applicable PLC

A: Available, N/A: Not available

Product name

Part number

Control CommX Ver. 1.3 

(OCX for Communication)

Control CommX IBM printer port

Control CommX USB port

AFW20011

AFW20031

Product name

Part number

FP Memory Loader

Data non-hold type

Data hold type

AFP8670

AFP8671

Product name

FP Web-Server Unit

FP Web-Server unit

FP Web Configurator Tool

Part number

AFP0610

AFPS30510

PCWAY Ver. 2.7 

(Operation Data Managing Software)

Product name

Part number

PCWAY USB port version

PCWAY Version upgrade

AFW10031

AFW10401

* Charged version upgrade for Ver. 2.0 to 2.6.

Product name

Part number

Key Unit

Economical type is available for secondary key.
The key unit is available for PCWAY and Control CommX.

Key unit USB port version

AFW1033

Содержание FP-X

Страница 1: ...RUN ERR FP X C14 7 4 0 0 3 4 Y X 3 V1 RUN PROG V0 5 X6 X4 X3 L N X7 X0 X2 COM X5 X1 Y1 Y0 0V 24V Y5 C0 C1 C2 C3 Y4 Y3 Y2 Panasonic ERROR I F POWER AFPX EFP0 AFPX C60 7 0 5 3 5 90 60 25 90 60 90 100 9...

Страница 2: ...re controllers and power meters General purpose Serial Communications Commands are generated transmitted in accordance with the communication protocol of the target equipment Or nonprocedural data rec...

Страница 3: ...re controllers and power meters General purpose Serial Communications Commands are generated transmitted in accordance with the communication protocol of the target equipment Or nonprocedural data rec...

Страница 4: ...t of 24 V DC 6 point output of 2 A relay 16 point input of 24 V DC 14 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A...

Страница 5: ...t of 24 V DC 6 point output of 2 A relay 16 point input of 24 V DC 14 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A...

Страница 6: ...ords 14 words 256 points 256 labels Up to program capacity 1000 stages 500 subroutines Relay output type 15 programs 14 external 1 constant Transistor output type 9 programs 8 external 1 constant 0 5...

Страница 7: ...ords 14 words 256 points 256 labels Up to program capacity 1000 stages 500 subroutines Relay output type 15 programs 14 external 1 constant Transistor output type 9 programs 8 external 1 constant 0 5...

Страница 8: ...with a transistor output type control unit Enables easy Ethernet connections with a compact PLC which have been previously abandoned Also equipped with an RS232C port Together with the tool port prog...

Страница 9: ...with a transistor output type control unit Enables easy Ethernet connections with a compact PLC which have been previously abandoned Also equipped with an RS232C port Together with the tool port prog...

Страница 10: ...perfectly fits the need for low cost multi axis positioning control in small scale equipment Built in 4 axis Pulse Output Transistor Output Type The transistor output type C14 comes with 3 axis while...

Страница 11: ...perfectly fits the need for low cost multi axis positioning control in small scale equipment Built in 4 axis Pulse Output Transistor Output Type The transistor output type C14 comes with 3 axis while...

Страница 12: ...e FP X as a slave automatically sends responses to MEWTOCOL commands sent from a master station such as a personal computer up to 3 communication ports Computer link MEWTOCOL slave General purpose ser...

Страница 13: ...e FP X as a slave automatically sends responses to MEWTOCOL commands sent from a master station such as a personal computer up to 3 communication ports Computer link MEWTOCOL slave General purpose ser...

Страница 14: ...ided for data and real time clock One battery for C14 two for C30 and three for C60 can be attached A two battery installation can operate for a long time 10 years or more without maintenance Real tim...

Страница 15: ...ided for data and real time clock One battery for C14 two for C30 and three for C60 can be attached A two battery installation can operate for a long time 10 years or more without maintenance Real tim...

Страница 16: ...64 MB depends on OS At least 1024 768 High Color 16 bit or higher FP X FP e FP0 FP FP1 FP M FP2 FP2SH FP3 FP10SH Relay output type Ver 5 1 and after Transistor output type Ver 5 3 and after 17 16 Pro...

Страница 17: ...64 MB depends on OS At least 1024 768 High Color 16 bit or higher FP X FP e FP0 FP FP1 FP M FP2 FP2SH FP3 FP10SH Relay output type Ver 5 1 and after Transistor output type Ver 5 3 and after 17 16 Pro...

Страница 18: ...ond day of week optional battery required RS232C 1 ch RS and CS control signal equipped non insulated RS232C 2 ch non insulated RS485 RS422 selectable 1ch insulated RS485 1 ch insulated RS232C 1 ch no...

Страница 19: ...ond day of week optional battery required RS232C 1 ch RS and CS control signal equipped non insulated RS232C 2 ch non insulated RS485 RS422 selectable 1ch insulated RS485 1 ch insulated RS232C 1 ch no...

Страница 20: ...d terminal cable 5 A PNP 0 1 A 24 V DC transistor output type is also available When ordering it please replace T in the end of product number for the NPN type with P Control FPWIN Pro IEC61131 3 comp...

Страница 21: ...d terminal cable 5 A PNP 0 1 A 24 V DC transistor output type is also available When ordering it please replace T in the end of product number for the NPN type with P Control FPWIN Pro IEC61131 3 comp...

Страница 22: ...n Over voltage category 100 to 240 V AC AC power 24 V DC DC power 85 to 264 V AC AC power 20 4 to 28 8 V DC DC power C14 24V DC 0 15A C30 and C60 24V DC 0 4A 10 ms or more 0 to 55 C 40 to 70 C 10 to 9...

Страница 23: ...n Over voltage category 100 to 240 V AC AC power 24 V DC DC power 85 to 264 V AC AC power 20 4 to 28 8 V DC DC power C14 24V DC 0 15A C30 and C60 24V DC 0 4A 10 ms or more 0 to 55 C 40 to 70 C 10 to 9...

Страница 24: ...RUN ERR FP X C14 7 4 0 0 3 4 Y X 3 V1 RUN PROG V0 5 X6 X4 X3 L N X7 X0 X2 COM X5 X1 Y1 Y0 0V 24V Y5 C0 C1 C2 C3 Y4 Y3 Y2 Panasonic ERROR I F POWER AFPX EFP0 AFPX C60 7 0 5 3 5 90 60 25 90 60 90 100 9...

Отзывы: