Panasonic FP-X Скачать руководство пользователя страница 7

Basic Performance (High capacity/High speed)

Basic Performance (Expansion)

The high-level basic performance provides sufficient room for future 

equipment expansion as well as a rich variation.

7

 Abundant program capacity - 

32

 

ksteps (16 ksteps for C14)

 High-speed scan at 

0.32

 

µ

sec for instruction processing

 Abundant number of I/O points - Maximum 

300

 

(Up to 382 points possible by using FP0 expansion units and add-on cassettes)

 Expansion units (E16R, E30R, EFP0) can be connected up to eight units.

 Connection by using the cable included in each expansion unit.

Max. 

300

 channels

Max. 8 units

 Two or more E16 can't be connected serially.

 E16 can be sandwiched with E30*

* E30 requires an external power supply

Note: Total expansion cable length: 160 cm max.

An 80-cm expansion cable is 
also available as an option.

E30

E30

E30

C60

E30

E30

C60

C60

E16

E16

C60

E16

E30

When the user cannot predict the number of I/O points required in the future for his machine or equipment, he is 
uncertain in selecting a PLC model. FP-X solves user concerns with a maximum of 300 I/O channels. The number 
can even be increased up to 382 points by using the add-on cassettes and FP0 expansion units.

 When further expansion or functions are required, use the existing 

FP0 expansion unit.

Max. 7 units (210 points)

Max. 96 points

Expansion FP0 adapter (AFPX-EFP0)

The unified unit height of 90 mm makes 
the panel surface look clean.

E30

E30

C60

Controls Specifications

 Equipped with an independent comment memory

Equipped with an independent comment memory separate from the program memory.

All of 

100,000

 I/O comments, 

5,000

 lines of line-space comments, and 

5,000

 lines 

of remark comments are saved in FP-X together with programs.

*Input comments do not decrease the program capacity.

The program capacity of 32 ksteps, exceeding the capacity of most compact PLCs, 
can flexibly handle a wide variety of applications requiring future equipment 
expansion. An adequate comment area has of course been reserved. Free comment 
entry makes the program easy to understand during verification.

C14

C30, C60

C14

32

k

10

k

16

k

FP0

FP-X

C30/C60

FP-X

10k

20k

30k

steps

Program capacity

High-speed processing is often required for small-scale equipment control 
such as serial data communication, network construction or PID temperature 
control. High-speed scanning at 0.32 

µ

sec/step (basic instruction) easily meets 

such requirements.

(Ex.) In the case of a 5-kstep program consisting of 40% basic instructions 

and 60% applied instructions (Data tansfer and operation instructions), 

 Scan time: 

1.9 ms

 

(measured time)

0.5

1.0

0.32 

µ

sec

0.9 

µ

sec

µ

sec

FP-X

FP0

Processing speed of the basic 

instructions (ST, OR, AND, OT etc)

NG

OK

The units can be tightly 
mounted adjacent to each 
other with the cable bent 
inside between the units for 
saving space.

All control units can be expanded by up to 3 FP0 expansion units via an adapter.
Applications can be expanded by using [Transistor outputs], [Analog input/outputs], 
[Thermocouple input] and [I/O link (network)].

* Only one expansion FP0 adapter unit can be attached to a control unit.

Up to 7 FP-X expansion units can be used when the expansion FP0 adapter is attached.

6

Item

Specifications

Item

Specifications

Program method

Control method

Program memory

Program capacity

Operation processing speed

Basic instructions

Applied instructions

External inputs (X)

External outputs (Y)

Internal relay (R)

Special internal relay (R)

Link relay (L)

Timer/counter (T/C)

Data register (DT)

Link data register (LD)

Special data register (DT)

Index register (I0 to ID)

Master control relay (MCR)

Number of labels (LOOP)

Number of differentiations

Number of stepladders

Number of subroutines

Number of interruption programs

High-speed counter 

*2

Relay symbol method

Cyclic operation method

Flash ROM built-in (no battery backup required)

16 ksteps (C14), 32 ksteps (C30, C60)

Basic instruction 0.32 

µ

s/step

111

216

1760 points 

*1

1760 points 

*1

4096 points 

192 points 

2048 points 

12285 words (C14), 32765 words (C30, C60)

256 words

374 words

14 words

256 points

256 labels

Up to program capacity

1000 stages

500 subroutines

Relay output type: 15 programs (14 external, 1 constant)
Transistor output type: 9 programs (8 external, 1 constant)

0.5 ms to 30 s

2 points (0 to 1000) (C14, C30)  4 points (0 to 1000) (C60)

Possible

Equipped (usable only when AFPX-MRTC is installed) 

*5

Data register (32765 words)

Counter 16 points (1008 to 1023), Internal relay 128 points 

(R2480 to R255F), Data register 55 words

The memory allocated in the storage area by the 

system register (only when a battery is installed) 

*6

C14: 1230 days (actual operation 10 years at 25

°

C)

C30, C60: 990 days (actual operation 10 years at 25

°

C)

C14: 780 days (actual operation 10 years at 25

°

C)

C30, C60: 680 days (actual operation 10 years at 25

°

C)

(More than two batteries can be installed in C30 and C60. 
In this case, the battery life is extended several times)

Capable (4 or 8 characters selectable)

Watch dog timer, program syntax check

Capable (328 KB) (backup battery not required)
All of I/O comments, remark comments, and line-space comments can be stored.

Max 16 units, link relay 1024 points, link register 128 words 

(No data transfer or remote programming)

Capable

Backup by F12, 
P13 commands

Auto-backup 
at power failure

(when no power is 
supplied)

After installing 
AFPX-MRTC

Before installing 
AFPX-MRTC

*1 The actual usable number of points is restricted by the hardware.
*2 Specification at the rated input voltage of 24 V DC, 25

°

C. Frequency may be lower due to the voltage and 

temperature. The countable frequency also changes depending on the number of channels used.

*3 The pulse I/O cassette cannot be used for the control units (transistor output type).

*4 Max frequency may vary by the method of operation. Please refer to the manual for details.
*5 Calendar accuracy at 0

°

C: 119 sec/month or less, 25

°

C: 51 sec/month or less, 55

°

C: 148 sec/month or 

less (Real-time clock requires a battery.)

*6 When data is stored in the storage area while the battery is not installed, the data is not cleared and the 

data value may be indefinite. The same condition occurs when the battery is exhausted.

*7 The number of possible rewrites is 10,000 or less.

Built-in (Transistor output): 100 kHz x 2 ch + 20 kHz x 2 ch
Pulse I/O cassette (for the relay output type only): 
One unit (one axis) 100 kHz, or two units (two axes) 80 kHz

Relay output type: Total 14 points (including the high-speed counter)
Transistor output type: Total 8 points (including the high-speed counter)

Total 1024 points: timer capable of counting 
(1 ms, 10 ms, 100 ms, 1 s) x 32767
Counter capable of counting 1 to 32767

Pulse catch input / interrupt input

Periodical interrupt

Potentiometer

Constant scan

Real-time clock

Flash ROM
backup 

*7

Battery backup

Battery life 

   

Password

Self-diagnosis function

Comment storage

PLC link function

Rewriting in RUN mode

Pulse output 

*4

Built-in (Transistor output): single-phase 8 ch (50 kHz x 4 ch + 10 kHz x 4 ch)
Built-in (Relay output): single-phase 8 ch (10 kHz x 8 ch)
Pulse I/O cassette 

*3

: single-phase 2 ch (80 kHz x 2 ch)

In addition to the supplied 8-cm expansion cable, 30-cm and 80-cm types are available as options, 

allowing the units to be arranged more freely. (Total expansion cable length: 160 cm max.)

FP0-E8X
FP0-E16X
FP0-E8YT
FP0-E8YRS
FP0-E16YT

FP0-E32T

FP0-E8RS

FP0-E16RS

FP0-A21
FP0-A80
FP0-A04V
FP0-A04I
FP0-TC4
FP0-TC8

FP0-IOL
FP0-CCL

FP0-E32RS*

2

FP0-RTD6*

2

FP0-DPS2*

2

Product number

Product number

Specifications

Specifications

8 ch. DC input, MIL connector

16 ch. DC input, MIL connector

8 ch. transistor output, MIL connector
8 ch. relay output, screw terminal block

16 ch. transistor output, MIL connector

16 ch. DC input, 16 ch. transistor output, 

MIL connector

4 ch. DC input, 4 ch. relay output, 
screw terminal block

8 ch. DC input, 8 ch. relay output, 
screw terminal block

Analog 2 ch. input, 1 ch. output
Analog 8 ch. input
Analog (voltage) 4 ch. output
Analog (current) 4 ch. output
Thermocouple 4 ch. input
Thermocouple 8 ch. input

I/O link unit
CC-link unit

16ch DC input, 16ch relay output 
screw terminal block
6ch RTD input
PROFIBUS remote I/O unit

*2 Provided from Panasonic Electric Works Europe AG

We also have other units. Please refer to the part number 
list at the end of this catalog.

Содержание FP-X

Страница 1: ...RUN ERR FP X C14 7 4 0 0 3 4 Y X 3 V1 RUN PROG V0 5 X6 X4 X3 L N X7 X0 X2 COM X5 X1 Y1 Y0 0V 24V Y5 C0 C1 C2 C3 Y4 Y3 Y2 Panasonic ERROR I F POWER AFPX EFP0 AFPX C60 7 0 5 3 5 90 60 25 90 60 90 100 9...

Страница 2: ...re controllers and power meters General purpose Serial Communications Commands are generated transmitted in accordance with the communication protocol of the target equipment Or nonprocedural data rec...

Страница 3: ...re controllers and power meters General purpose Serial Communications Commands are generated transmitted in accordance with the communication protocol of the target equipment Or nonprocedural data rec...

Страница 4: ...t of 24 V DC 6 point output of 2 A relay 16 point input of 24 V DC 14 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A...

Страница 5: ...t of 24 V DC 6 point output of 2 A relay 16 point input of 24 V DC 14 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A relay 32 point input of 24 V DC 28 point output of 2 A...

Страница 6: ...ords 14 words 256 points 256 labels Up to program capacity 1000 stages 500 subroutines Relay output type 15 programs 14 external 1 constant Transistor output type 9 programs 8 external 1 constant 0 5...

Страница 7: ...ords 14 words 256 points 256 labels Up to program capacity 1000 stages 500 subroutines Relay output type 15 programs 14 external 1 constant Transistor output type 9 programs 8 external 1 constant 0 5...

Страница 8: ...with a transistor output type control unit Enables easy Ethernet connections with a compact PLC which have been previously abandoned Also equipped with an RS232C port Together with the tool port prog...

Страница 9: ...with a transistor output type control unit Enables easy Ethernet connections with a compact PLC which have been previously abandoned Also equipped with an RS232C port Together with the tool port prog...

Страница 10: ...perfectly fits the need for low cost multi axis positioning control in small scale equipment Built in 4 axis Pulse Output Transistor Output Type The transistor output type C14 comes with 3 axis while...

Страница 11: ...perfectly fits the need for low cost multi axis positioning control in small scale equipment Built in 4 axis Pulse Output Transistor Output Type The transistor output type C14 comes with 3 axis while...

Страница 12: ...e FP X as a slave automatically sends responses to MEWTOCOL commands sent from a master station such as a personal computer up to 3 communication ports Computer link MEWTOCOL slave General purpose ser...

Страница 13: ...e FP X as a slave automatically sends responses to MEWTOCOL commands sent from a master station such as a personal computer up to 3 communication ports Computer link MEWTOCOL slave General purpose ser...

Страница 14: ...ided for data and real time clock One battery for C14 two for C30 and three for C60 can be attached A two battery installation can operate for a long time 10 years or more without maintenance Real tim...

Страница 15: ...ided for data and real time clock One battery for C14 two for C30 and three for C60 can be attached A two battery installation can operate for a long time 10 years or more without maintenance Real tim...

Страница 16: ...64 MB depends on OS At least 1024 768 High Color 16 bit or higher FP X FP e FP0 FP FP1 FP M FP2 FP2SH FP3 FP10SH Relay output type Ver 5 1 and after Transistor output type Ver 5 3 and after 17 16 Pro...

Страница 17: ...64 MB depends on OS At least 1024 768 High Color 16 bit or higher FP X FP e FP0 FP FP1 FP M FP2 FP2SH FP3 FP10SH Relay output type Ver 5 1 and after Transistor output type Ver 5 3 and after 17 16 Pro...

Страница 18: ...ond day of week optional battery required RS232C 1 ch RS and CS control signal equipped non insulated RS232C 2 ch non insulated RS485 RS422 selectable 1ch insulated RS485 1 ch insulated RS232C 1 ch no...

Страница 19: ...ond day of week optional battery required RS232C 1 ch RS and CS control signal equipped non insulated RS232C 2 ch non insulated RS485 RS422 selectable 1ch insulated RS485 1 ch insulated RS232C 1 ch no...

Страница 20: ...d terminal cable 5 A PNP 0 1 A 24 V DC transistor output type is also available When ordering it please replace T in the end of product number for the NPN type with P Control FPWIN Pro IEC61131 3 comp...

Страница 21: ...d terminal cable 5 A PNP 0 1 A 24 V DC transistor output type is also available When ordering it please replace T in the end of product number for the NPN type with P Control FPWIN Pro IEC61131 3 comp...

Страница 22: ...n Over voltage category 100 to 240 V AC AC power 24 V DC DC power 85 to 264 V AC AC power 20 4 to 28 8 V DC DC power C14 24V DC 0 15A C30 and C60 24V DC 0 4A 10 ms or more 0 to 55 C 40 to 70 C 10 to 9...

Страница 23: ...n Over voltage category 100 to 240 V AC AC power 24 V DC DC power 85 to 264 V AC AC power 20 4 to 28 8 V DC DC power C14 24V DC 0 15A C30 and C60 24V DC 0 4A 10 ms or more 0 to 55 C 40 to 70 C 10 to 9...

Страница 24: ...RUN ERR FP X C14 7 4 0 0 3 4 Y X 3 V1 RUN PROG V0 5 X6 X4 X3 L N X7 X0 X2 COM X5 X1 Y1 Y0 0V 24V Y5 C0 C1 C2 C3 Y4 Y3 Y2 Panasonic ERROR I F POWER AFPX EFP0 AFPX C60 7 0 5 3 5 90 60 25 90 60 90 100 9...