7-20
7.8
41B
Parameter Settings
Set the initial operation for the positioning unit RTEX.
1. Select [Set axis]
→
[Parameter settings] in the menu bar, or click the [Parameter setting] icon
in the toolbar.
2. The parameter setting dialog is shown. Set the parameters.
Setting items
Parameter name
Description
Unit setting
The unit to be used for setting each axis.
Pulse number per rotation
The pulse number per rotation.
(It should be cancelled down with the movement amount per
rotation.)
Movement amount per rotation
The movement amount per rotation.
(It should be cancelled down with the pulse number per
rotation.)
CW/CCW direction setting
The directions of CW and CCW.
CW+: + direction is CW.
CCW+: + direction is CCW.
Limit switch
Enable/disable the limit switch.
Limit switch connection
The connections of the + direction limit switch and - direction
limit switch.
Standard: + direction limit is CWL. - direction limit is CCWL.
Reverse connection: + direction limit is CCWL. - direction limit
is CWL.
Software limit (Positioning control)
Enable/disable the software limit in the positioning control.
Software limit (Home return)
Enable/disable the software limit in the home return.
Software limit (JOG operation)
Enable/disable the software limit in the JOG operation.
Upper limit of software limit
The upper limit value of the software limit.
Lower limit of software limit
The lower limit value of the software limit.
Auxiliary output mode
Enable/disable the auxiliary output contact and auxiliary output
code.
Auxiliary output ON time (ms)
The time that the auxiliary output contact is ON.
Содержание FP? Positioning Unit RTEX
Страница 1: ......
Страница 6: ...iv ...
Страница 14: ...xii ...
Страница 15: ...Chapter 1 Functions of Unit and Restrictions on Combination ...
Страница 21: ...Chapter 2 Parts and Functions ...
Страница 22: ...2 2 2 1 Parts and Functions FPΣ Positioning Unit RTEX FP2 Positioning Unit RTEX ...
Страница 24: ...2 4 ...
Страница 25: ...Chapter 3 Wiring ...
Страница 27: ...3 3 3 2 Network Connector RJ45 plug is connected to the network connector Pins of RJ45 plug Connecting diagram ...
Страница 31: ...Chapter 4 Power On Off and Items to Check ...
Страница 36: ...4 6 ...
Страница 37: ...Chapter 5 4BPreparation For Operation ...
Страница 45: ...Chapter 6 5BI O Allocation ...
Страница 53: ...Chapter 7 6BSetting Tool Configurator PM ...
Страница 83: ...7 31 Setting Font Select Option Font in the menu bar The following dialog is shown ...
Страница 102: ...7 50 ...
Страница 103: ...Chapter 8 7BAutomatic Operation Position Control ...
Страница 118: ...8 16 ...
Страница 119: ...8 17 When the X axis and Y axis is the moving axes each axis in the above diagram is replaced ...
Страница 141: ...Chapter 9 8BManual Operation JOG Operation ...
Страница 146: ...9 6 ...
Страница 147: ...Chapter 10 9BManual Operation Home Return ...
Страница 155: ...Chapter 11 10BManual Operation Pulser Operation ...
Страница 159: ...Chapter 12 11BStop Functions ...
Страница 162: ...12 4 ...
Страница 163: ...Chapter 13 12BSupplementary Functions ...
Страница 177: ...13 15 Sample program When reading AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Страница 179: ...13 17 Sample program When writing AMP parameter No 1 1 of axis 1 with A6N or A5N ...
Страница 183: ...Chapter 14 Precautions During Programming ...
Страница 187: ...Chapter 15 Errors and Warnings ...
Страница 212: ...15 26 ...
Страница 213: ...Chapter 16 Troubleshooting ...
Страница 214: ...16 2 16 1 Cannot Communication With AMP ...
Страница 215: ...Chapter 17 Specifications ...
Страница 275: ...Chapter 18 Dimensions ...
Страница 276: ...18 2 18 1 FPSigma Positioning Unit RTEX ...
Страница 277: ...18 3 18 2 FP2 Positioning Unit RTEX ...
Страница 278: ...18 4 ...
Страница 279: ...Chapter 19 Sample Programs ...
Страница 283: ...19 5 ...
Страница 286: ...19 8 ...
Страница 288: ......