The sensor can detect the pollution of the air, and show the pollution level by indicator. The
product can optimize the air volume automatically in auto operation according to the air quality.
About odor sensor/dirt sensor
Stop operating the product, then press and buttons at the same time for about
3 seconds. The indicator will light on in sequence as illustrated below.
The sensitivity of the sensor can be adjusted. (The default setting is “medium sensitivity” .)
Please release the buttons, when the
sensitivity is set as required.
Medium sensitivity
High sensitivity
Low sensitivity
The sensor’s operation may vary depending on the indoor airflow condition if a heater is placed
near the product in a room.
The sensor is not designed to detect bacteria and viruses.
FURTHER INFORMATION
Super Allergy-buster: inhibits the activity of allergic substances (pollen, dead mites and feces).
The HEPA composite filter which with the Bio-sterilization and Super Allergy-buster can inhibit
allergens (pollen, dead mites and feces), bacteria, mold.
The HEPA composite filter might emit unique and harmless smell of “Green Tea Catechin”,
”Bio-sterilization” and “Super Allergy-buster”.
About HEPA composite filter
About Econavi
Econavi mode refers to the automatic operation by combining the “patrol mode” in which the prod-
uct detects the dirt in the air in the room every hour with the “learning mode” in which the product
can forecast the dirt generation by mastering the generation time of dirt every day.
Automatically stops operating when the clean air is detected, meanwhile it also operates in advance
to eliminate the dirt effectively before spreading, thus reducing the operation time and saving power.
The product will stop operating automatically after the air is cleaned.
After the operation is paused for 50 min, the product will operate for 10
min with air volume set to “Med” in the patrol mode. While the opera-
tion is paused in the patrol mode, the product will operate with the
suitable air volume corresponding to the dirtiness detected.
The product records the time and dirtiness of air during operation, and takes the preventive opera-
tion 5 min before the recorded dirt is generated in the next day.
(Although the records are updated every day, the previous records will be lost once the power plug is
disconnected.)
Testing authority: Osaka Municipal Technical Research Institute
Test method: check the decrease of refined house dust mite allergen, by using enzyme immune
measuring method.
Inhibiting method: contact with Super Allergy-buster
Target: allergens trapped by the filter (mites, pollen)
Test result: inhibited 99% and above. (Daikou research report No. 2127)
OTHER
INFORMAT
ION
After replacement, please connect power plug, then press and buttons at the same
time for about 3 seconds until the filter replacement indicator turns off, then the reset is completed.
Fill in installation date on the label in filter case, then stick it on product to cover the old date. (P.7)
13
Patrol mode
Learning mode
Sensing scope
Odor sensor
Dirt sensor
Odor from cigarettes, incense, cooking, pets
Cosmetics, alcohol, sprays, etc.
PM2.5 (0.7~2.5 µm particles)
Humidity (water vapor), oil
Oil, fog-stated water drip
Indoor dust (dust, dead bodies and excreta
of ticks, mold spores, pollens, etc.)
Smog (cigarettes, incenses, etc.)
The wind generated when a door
is opened or closed, or sudden
temperature changes
May detect
Sensor