25
English
Problem
Possible cause
Action
The appliance can only be used
for a few minutes after charging.
The battery has reached the end of its
life. (approximately 3 years)
(See page 27.)
Please contact the store where
purchased.
(Customers cannot replace the
battery as doing so may cause
malfunction.)
The titanium head does not warm
up.
The appliance is being used in an
ambient temperature approximately
lower than 15 °C.
Use the appliance in an ambient
temperature approximately
15 °C or higher.
The appliance has not been charged.
Charge the appliance.
(See page 15.)
Temperature level is set to “OFF”.
Set temperature level to “LOW”,
“MED” or “HIGH”.
(See page 19.)
The titanium head does not
become cool.
Use the appliance in an ambient
temperature approximately 35 °C or
higher.
We recommend using the
appliance in an ambient
temperature range of 15 °C –
35 °C.
The appliance has not been charged.
Charge the appliance.
(See page 15.)
The air inlet or air outlet is blocked.
Do not block the air inlet or air
outlet.
COOLING mode has been used
continuously.
Do not use COOLING mode
continuously.
The titanium head becomes warm
a while after the power is turned
off.
After COOLING mode is used, the
titanium head temporarily becomes warm
for a while after the power is turned off.
This is not a fault.
PB017050 - EH-XT20 ������_(01EN)_11-27-18.indd 25
2018/11/27 16:55:30